Recirculating Air Control System



    Recirculating Air Control System



    Description & Application:

    1. Widely used in the semiconductor device for testing high and low temperature.
    2. Independent refrigerated air recirculating unit.
    3. Can work for a long time continuously, defrosting automatically and it can not affect the storage temperature in the process of defrosting.
    4. Modular design and replace easily for standby machine,(If there are 10 sets of machines, only one standby machine is enough).
    5. Solve the problems of open or close the door frequently and frosting problem in evaporation system, it will not affect the temperature of the cold storage&cryogenic box in the process of defrosting in evaporation system.
    6. Easy installation (joint the box according to mechanical drawing, connect the electricity and water and set temperature completely to work).

     Technical Parameters:

    Model
    AI-635W
    AI-655W
    AI-6A10W
    AI-835W
    AI-805W
    AI-810W
    Recirculating air temperature range ℃
    -65℃~125℃
    -65℃~125℃
    -65℃~125℃
    -85℃~125℃
    -85℃~125℃
    -85℃~125℃
    Control mode
    PID adaptive controller
    Communication protocol
    MODBUS RTU Protocol, RS 485 Interface
    Temperature feedback
    PT100
    Input & display
    7-inch color touch screen controller, temperature curve record, data export to excel format.
    Temp. accuracy
    ±0.2℃
    Heating power
    3.5kW
    5.5kW
    10kW
    3.5kW
    5.5kW
    10kW
    Cooling  capacity
    125℃
    3.5kW
    5.5kW
    10kW
    3.5kW
    5.5kW
    10kW
    50℃
    3.5kW
    5.5kW
    10kW
    3.5kW
    5.5kW
    10kW
    20℃
    3.5kW
    5.5kW
    10kW
    3.5kW
    5.5kW
    10kW
    0℃
    3.5kW
    5.5kW
    10kW
    3.5kW
    5.5kW
    10kW
    -20℃
    3kW
    4.2kW
    7.8kW
    3.5kW
    5.5kW
    10kW
    -40℃
    2.1kW
    3.2kW
    4.6kW
    2.5kW
    3.9kW
    7.1kW
    -55℃
    0.8kW
    1.2kW
    2.2kW
    1.6kW
    2.4kW
    4.2kW
    -75℃



    0.9kW
    1.3kW
    2.2kW
    Circulating air flow
    400m3/h
    900m3/h
    1300m3/h
    400m3/h
    900m3/h
    1300m3/h
    Connection size(outlet/inlet air)
    DN-100
    DN-100
    DN-125
    DN-100
    DN-100
    DN-125
    Compressor
    Scroll Copeland Compressor
    Evaporator
    Copper pipe aluminium fin (LNEYA)
    Safety protection
    Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,
    liquid low level protection, high temperature protection and temperature fault protection.
    Defrosting device
    There are installed defrosting device and condensate drain inside
    Continuous work
    Can work continuously
    Timing on & off operation
    Can set a key time for starting up & stop
    Refrigerant
    R404A R508B
    R404A R508B
    R404A R508B
    R404A R508B
    R404A R508B
    R404A R508B
    Air pressure
    4bar
    5bar
    5bar
    4bar
    5bar
    5bar
    Water-cooled W (temp.20 degree)
    1200L/H
    1.5bar~4bar
    1800L/H
    1.5bar~4bar
    3200L/H
    1.5bar~4bar
    1600L/H
    1.5bar~4bar
    2600L/H
    1.5bar~4bar
    3400L/H
    1.5bar~4bar
    Product Dimension
    650*750*1500
    700*800*1650
    700*800*1650
    650*750*1500
    700*800*1650
    700*800*1650
    Weight (water cooled)
    280kg
    315kg
    380kg
    300kg
    360kg
    420kg
    Power
    AC 380V 50HZ
    7.5kW (max)
    AC380V 50HZ
    10.5kW (max)
    AC 380V 50HZ
    19kW (max)
    AC380V50HZ
    9kW (max)
    AC380V50HZ
    12kW (max)
    AC380V50HZ
    22kW (max)
    Case material
    SUS 304
    SUS 304
    SUS 304
    SUS 304
    SUS304
    SUS304

    How to clean air control system?

    In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the air control systems, it is still necessary to have some knowledge of maintenance, and the most important thing to maintain is to say clean. Here, Guanya Refrigeration introduces some small methods for cleaning the air cooling system:

    More traditional methods are scraping and brushing. Sweep the place where you need to clean and the brush. The dirt that cannot be easily wiped off can be scraped with a sword. The second step is to use high-pressure water or chemical cleaning (mainly pickling), only to get high-pressure water or chemical water in the place where there is dirt to carry out chemical reactions, so that the dirt can be off.

    However, this more traditional method does not generally clean thoroughly, and cleaning with chemical water may also cause corrosion to the equipment and damage the machine. After the chemical waste has been washed away, it will take a lot of money to process it. Therefore, cleaning agents can be used. This is also relatively environmentally friendly, safe, and thorough in cleaning. Generally, oxidation does not occur, which is beneficial to the service life of the air cooling system.



    Contact Lneya for more.