Lab Chiller CDLJ -115℃~-50℃



    Lab Chiller CDLJ -115℃~-50℃



    -115℃~-50℃

     Technical Parameters:

    Lab chiller information: Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.
    Medium-sized low-temperature freezer, refrigeration temperature range from -155℃ ~ -50℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.

    ModelCDLJ-2WCDLJ-3WCDLJ-4WCDLJ-6WCDLJ-10WCDLJ-15WCDLJ-20WCDLJ-30WCDLJ-45WCDLJ-60WCDLJ-120W
    Temp. range-115°C~ -50°C
    Cooling capacity3kw4.5kw6kw9kw15kw22.5kw30kw45kw67.5kw90kw180kw
    At -90°C Kcal/h2580387051607740129001935025800387005805077400154800
    Cooling capacity2kw3kw4kw6kw10kw15kw20kw30kw45kw60kw120kw
    At -110°C Kcal/h172025803440516086002580017200258003870051600103200
    Circulation pump6.6m³/h6.6m³/h6.6m³/h15m³/h15m³/h15m³/h25m³/h25m³/h35m³/h35m³/h50m³/h
    2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar
    Connection sizeDN-25
    PN-10
    DN-25
    PN-10
    DN-25
    PN-10
    DN-32
    PN-10
    DN-32
    PN-10
    DN-32
    PN-10
    DN-40
    PN-10
    DN-40
    PN-10
    DN-50
    PN-10
    DN-50
    PN-10
    DN-50
    PN-10
    Cooling water
    30 DEG
    10m³/h14m³/h20m³/h25m³/h35m³/h45m³/h65m³/h90m³/h120m³/h180m³/h360m³/h
    Cool storage tank
    (optional)
    100L150L150L250L300L500L500L750L1000L1500L2000L
    Expansion tank
    (optional)
    50L75L100L150L200L300L300L400L550L800L1000L
    CompressorStandard: Dorin semi-closed compressorStandard: Hanbell screw compressor
    Optional: Bitzer screw compressor
    Operation panel7 inch color touch screen display input, temperature curve record.
    Control systemStandard: single chip microcomputer controller, position setting to open refrigeration 
    and close refrigeration temperature difference.
    Optional: Siemens S7 series PLC and module.
    Circulation systemThe whole system is fully closed system. The heat conduction medium does not absorb 
    the water in the air and will be replenished automatically at low temperature. The system
    will not increase the pressure due to the high temperature in the operation.
    Circulation pumpWuxi guanya tube type centrifugal pump.
    EvaporatorStandard: Brazing plate heat exchanger.
    Optional: stainless steel tube heat exchanger.
    CondenserShell and tube type water cooled condenser.
    Intermediate
    heat exchanger
    Plate heat exchanger.
    Drying filterEmerson
    Dry filter elementEmerson
    Expansion valveEmerson
    Refrigeration
    solenoid valve
    Emerson
    Oil separatorEmerson
    Pressure protectorEmerson
    ReservoirStandard:Ruishipu            Optional: Emerson
    Sight glassesStandard: Sanhua  Optional: Danfoss
    Refrigeration
    ball valve
    Standard: Sanhua  Optional: Danfoss
    ElectricitySchneider electric contact, schneider intermediate relay.
    RefrigerantR404A
    Secondary
    refrigerant
    Ethanol, dichloromethane, heat conduction medium, etc.
    Security and
    protection
    High pressure protection, water break protection, current protection, leakage protection, 
    continuous and broken phase protection, high temperature protection, sensor fault alarm, 
    low level alarm and other multiple security protection.
    Level indicatorGlass level indication
    Piping materialSUS304
    Expansion tank
    volume
    SUS304
    Shell materialChannel steel + square pipe + cold rolled steel
    Power supply
    (max)
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    14kw18kw30kw43kw69kw101kw101kw200kw295kw396kw768kw
    Dimension cm205*145
    *175
    205*145
    *175
    235*145
    *175
    300*150
    *205
    350*150
    *205
    350*180
    *205
    400*180
    *205
    450*180
    *205
    500*200
    *225
    550*220
    *235
    800*280
    *255
    NoiseWithin 75dbWithin 80dbWithin 90db
    How Long Does the Cold Water Machine in the Lab Need to be Cleaned?
    After running for a period of time, Lab Chiller CDLJ -115℃~-50℃ requires for the protection and the maintenance of all. If the laboratory chillers lack the necessary maintenance and protection, it means the high operation defect rate of the laboratory chiller.

    When running laboratory cold water machine, it needs a thorough clean for the machine to keep the laboratory machine safe and stable after using half a year's time.

    If cooling water machine for laboratory use frequency is higher, and the environment is relatively bad, to avoid the probability of all kinds of problems of industrial laboratory cold water machine, you should be able to shorten the clean time to once every three months.

    The specific time about cleaning the laboratory water chiller is determined by using environment of the company. If the environment is relatively clean, the company can put off cleaning time, whereas company needs to clean it ahead of schedule in order to keep the laboratory chiller operation safe, prevent all kinds of problems in case to affect the company normal use of laboratory chiller.



    Contact Lneya for more.