Walk-in Chamber

Walk-in Chamber


Application:

Applicable to aerospace products, information electronic instruments, materials, electricians, electronic products, various electronic components in high and low temperature or humid heat environment, testing its various performance indicators.

Characteristics:

Wide temperature control range can meet the user's various needs.
Unique balanced temperature control method, a stable and balanced heating capacity can be used for high precision and high stable temperature control.
The temperature displayed by touch screen, easy to read, precise and convenient.
The temperature error can be adjusted to meet your more accurate test conditions.
Automatically selecting and running the cooling circuit with the setting of temperature, with simple operation.
The door is equipped with a large observation window, which can observe the test status of the sample.
With high temperature starting function, the chamber can be turned on when the temperature in  rises to 100 degrees. It is convenient for continuous round-trip test between high temperature and low temperature.
With self-diagnosis function, overload protection , high pressure switch, overload relay, thermal protection device, etc.
With multi-wing fan used to circulate and avoid any dead Angle, so that the temperature can be distributed evenly in the test area.
The air circuit is designed with the wind return wind, the wind pressure and wind speed are in accordance with the test standard, and can make the opening instant temperature regain fast.
Heating, cooling, and completely independent system can improve efficiency, reduce test cost, increase life span and reduce failure rate.
The water tank is placed on the side of the unit with water shortage and automatic protection.
The humidifying system is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline to improve the safety.
The system of waterway system is opened by door to facilitate maintenance and repair.
In the refrigeration system, the condensation adopts air - cooling mode or water - cooling mode.

 Technical parameters:

Temp. range
(-40℃、-70℃)~ +100℃
Humidity range
25%R.H ~95%R.H
Temp. accuracy
±0.5℃
Rate
0.5℃/min~10℃/min

Volume
Inner dimension
Outside dimension
Overall Dimension
Gate size
6m3
1600×1800×2000
1950×2550×2380
1950×(3150~3750)×2380
1000×2000
8m3
2000×2000×2000
2350×2750×2380
2350×(3350~3950)×2380
1000×2000
10m3
2000×2500×2000
2350×3250×2380
2350×(3850~4450)×2380
1000×2000
11m3
2800×2000×2000
3150×2750×2380
3150×(3350~3950)×2380
1000×2000
12m3
3000×2000×2000
3350×2750×2380
3350×(3350~3950)×2380
1000×2000
14m3
2700×2300×2300
3050×3050×2680
3050×(3650~4250)×2650
1000×2000
16m3
4000×2000×2000
4350×2750×2380
4350×(3350~3950)×2380
1000×2000
20m3
3000×3000×2200
3350×3750×2580
3350×(4350~4950)×2580
1600×2000
24m3
3000×2500×2500
3350×3250×2880
3350×(3850~4450)×2880
1600×2000
29m3
3000×3200×3000
3350×3950×3380
3350×(4550~5150)×3380
1600×2000
32m3
4200×3200×2200
4550×3950×2580
4550×(4550~5150)×2580
2000×2000
36m3
4000×3000×3000
4350×3750×3380
4350×(4350~4950)×3380
2000×2500
40m3
3600×4400×2500
3950×5150×2880
3950×(5750~6350)×2880
2000×2500
66m3
4200×8000×2000
4550×8750×2380
4550×(9350~10250)×2380
3000×2000