Sunday, June 10, 2018

Glycol Cooling Heating Control System



    Glycol Cooling Heating Control System



    Gycol heating and cooling system is connected to a testing adapter. Components cooling and the heating test is conducted by ethylene glycol aqueous. The whole component is in the environment storehouse which offers a high or low-temperature environment. The testing of components will have a specific temperature change temperature variation curve, it will record the temperature change temperature range is usually from - 40c to 150c.

    Application
    a. The glycol refrigeration system  is connected to a testing adapter.
    b. Components cooling and the heating test is conducted by ethylene glycol aqueous.
    c. The whole components ix in the environment storehouse which offers a high or low temperature environment.
    d. The testing of components will have a specific temperature variation curve, it will record the temperature change .Temperature range is usually from -40℃to 150℃.
    e. Tolerance tests are usually carried out in an infinite loop.

    Product Description
    The following are demanded parametric variation of continuous periods:
    a. The temperature range of ethylene glycol aqueous solution is from - 40℃to 150℃.
    b. The temperature range of environment room is - 50℃to 150℃.
    c. Very steep variations in the temperature gradient.
    d. The outlet temperature limit.
    e. Visualization, data storage, report analysis.
    f. Temperature control system can flexibly be connected to other testing platforms.

    TypeKRY-5A25W
    Medium Temp.range-45℃~150℃
    Control modeFeedforward PID+our special dynamic control calculation, PLC controller
    Temperature controlControl inner box temp.
    Program editor10 programs, each program can edit 45 steps
    Communication protocolMODBUS RTU protocol, RS 485 interface
    Temperature feedbacksingle temp.measuring
    Temp.accuracy±0.3℃
    Heating power9kw
    Cooling capacity150℃9kw
    100℃9kw
    20℃9kw
    0℃9kw
    -20℃9kw
    -40℃7kw
    -45℃4kw
    Internal circulation wind flow rate2400m³/h
    CompressorEmerson
    Expansion valveEmerson
    Oil separatorEmerson
    EvaporatorCopper aluminum-fin
    Operation panel7-inch touch screen, temperature curve record/excel data output
    Safety protectionSelf-diagnosis function; freezer overload protection; high-pressure switch; overload relay; thermal protection device, liquid low-level protection, high-temperature protection and temperature
    Closed circulation systemThe whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure does not rise up when the system is running. The system will supply oil automatically at low temperature.
    RefrigerantR-404A
    Connection sizePN10
    Water-cooled type W8.5m³/h 1.5bar~4bar cooling water@25℃
    Water-cooled condenserShell and tube exchanger
    Power380V 50HZ 57kw(max)