Ultra Low Temperature Recirculating Chillers LC -25℃~-5℃



    Ultra Low Temperature Recirculating Chillers LC -25℃~-5℃




    -25℃~-5℃

     Technical Parameters:

    Medium-sized low-temperature freezer, refrigeration temperature range from -25 ℃ ~ -5℃. The ultra low temperature recirculating chillers promise the operation to be safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
    Product Name
    Ultra-low Temperature Freezer
    Model
    LC-12W
    LC-20W
    LC-30W
    LC-40W
    LC-60W
    Temperature Range ℃
    -25°C~ 5°C
    Cooling Capacity At -20°C
    12kW
    20kW
    30kW
    40kW
    60kW
    10320Kcal/h
    17200Kcal/h
    25800Kcal/h
    34400Kcal/h
    51600Kcal/h
    Circulation Pump
    6.6m³/h
    2.5bar max
    9m³/h
    2.5bar max
    15m³/h
    2.5bar max
    15m³/h
    2.5bar max
    25m³/h
    2.5bar max
    Inlet&outlet connection size
    DN-25 PN-10
    DN-25 PN-10
    DN-32 PN-10
    DN-32 PN-10
    DN-40 PN-10
    Water-cooled type  W(cooling water at 30℃)
    8m³/h
    10m³/h
    16m³/h
    20m³/h
    25m³/h
    Cold storage tank(optional)
    200L
    350L
    500L
    750L
    1000L
    Expansion tank(standard)
    100L
    175L
    250L
    350L
    500L
    Compressor

    Standard:Copeland
    Optional:BOCK piston compressor
    Operation Panel
    7-inch color touch screen display, temperature curve record, data export to excel format.
    Control System
    Standard: Single-chip microcomputer controller; Stepping control; Set temperature difference of refrigeration on & off.
    Optional: SIEMENS S7-200PLC&Module
    Closed
    circulation system
    The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,
    pressure does not rise up when the system is running. The system will supplement oil automatically at low temperature.
    Circulation pump
    Standard:Direct type magnetic pump
    Optional: Increase the pipeline magnetic pump pressure in the pipeline
    Evaporator
    Standard: Braze welding plate heat exchanger (BPHE)
    Optional: Stainless steel tube heat exchanger
    Condenser
    Shell and tube type water cooled condenser
    Intermediate heat exchanger
    KAORI Plate heat exchanger
    Dry Filter
    Emerson
    Drying filter core
    Emerson
    Expansion tank
    Emerson
    FDF
    Emerson
    Oil separator
    Emerson
    Pressure protector
    Emerson
    Reservoir
    Standard:RSP
    Optional:Emerson
    Sight glass
    Standard: SANHUA           Optional: Danfoss
    Refrigeration ball valve
    Standard: SANHUA            Optional: Danfoss
    Electric
    Schneider AC contactor, Schneider intermediate relay
    Refrigerant
    R404A
    Secondary refrigerant
    No corrosive liquid, ethanol-water, ethylene glycol aqueous solution, heat transfer oil etc.
    Safety protection
    High pressure protect; Water-supply cut-off protection; Over-current protection; Leakage protection;
    Sequential and phase failure protection; High-temperature protection; Sensor Failure protection;
    Liquid low-level protection etc. muti-safety protection.
    Level Indicator
    Adpot glass liquid level indication
    Piping material
    SUS304
    Expansion tank material
    SUS304
    Case material
    Steel channel + Square tube + Cold-rolled blanking plate  painting
    Product size
    160*100*165
    160*100*165
    180*120*175
    180*120*175
    205*145*175
    Power
    380V 50HZ
    10kW max
    380V 50HZ
    14kW max
    380V 50HZ
    22kW max
    380V 50HZ
    31kW max
    380V 50HZ
    45kW max
    HP
    12HP
    15HP
    25HP
    35HP
    50HP
    dB
    75DB
    Within80dB
    Weight
    800kg
    950kg
    1200kg
    1350kg
    1500kg

    After running for a period of time, the normal operation of ultra-low temperature circulating water chiller needs comprehensive maintenance and maintenance. For many enterprises, due to the weak consciousness of daily maintenance, the cryogenic cycle water chiller has been used for a long time without maintenance. If the low-temperature cycle chiller is lack of necessary maintenance, the failure rate of the ultra-low temperature circulating water chiller will be pretty high in the later period.

    There will be a large range of incrustation problem after an industrial long-term cryogenic operation of circulating water chiller. If the incrustation cannot be effectively cleaned up, the range of incrustation will continuously extend after a long time of accumulation, which will directly affect the industrial circulation chillers of ultra-low temperature.

    If the ultra-low temperature recirculating chillers frequently used in a hostile environment, shorten the cleaning time to three months in order to reduce the probability of all kinds of malfunctions of the industrial ultra-low temperature chiller.

    As long as there are some problems such as the increase of energy consumption, the comprehensive cleaning, and maintenance of the industrial ultra-low temperature circulating water chiller can be carried out. Proper cleaning and maintenance can extend the service life of ultra-low temperature cycle chillers, and avoid all kinds of faults to affect the safe operation of industrial ultra-low temperature cycle chillers.



    Contact Lneya for more.