Saturday, June 9, 2018

High-Low Temp. Test Chamber

High-Low Temp. Test Chamber



Performance characteristics:

1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.
2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control can be carried out;The temperature is displayed by touch screen, easy to read, precise and convenient.
3. Adjust the temperature error value to meet more accurate test conditions.With the setting of temperature, it is easy to operate the refrigeration circuit.
4. The box door is equipped with a large observation window, which can observe the test status of the test sample at any time.
5. with functions of high temperature on, can open the refrigerator when the temperature in the oven to 150 ℃, facilitate continuous round-trip experiment was carried out between the high temperature and low temperature.
6. Self-diagnosis function, overload protection of refrigerator, high pressure switch, overload relay, thermal protection device, etc., to ensure the safety of use.
7. Use the multi-wing fan to supply the wind with strong air circulation and avoid any dead Angle, so that the temperature can be evenly distributed in the test area.
8. Wind circulation is designed with wind return wind. The wind pressure and wind speed are in accordance with the test standard.
9. Temperature rise, cooling and system complete independence can improve efficiency, reduce test cost, increase life span and reduce failure rate.

Technical Parameters:

ModelGD-4525GD-4550GD-45A0GD-7525GD-7550GD-75A0
cubage220L500L1000L220L500L1000L
Temp. range-45℃~+150℃-75℃~+150℃
Temp. accuracy±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
Temperature uniformity≤2℃
Heating rate2.8℃/min
Cooling rate2.5℃/min
Heating power2KW3.5KW5KW2KW3.5KW5.5KW
Nickel-chromium alloy electric heater, control itself has 2 protections, add independent 
temperature limiter
ControllerLNEYA  PLC AndModules
Program editorCan edit 15 programs, each program can be programmed 45 steps.
Touch screenLNEYA  7 inch color touch screen
Data recordTemperature curve record (can be exported to EXECL format by U disk), alarm information record.
CommunicationRS485 interface Modbus RTU protocol
CompressorEmerson Copeland Scroll Flexible CompressorFrance Taikang/ItalyDorin Compressor
Drying filterDanfoss/Emerson.
Oil separatorEmerson
expansion valveDanfoss thermal expansion valve.Danfoss thermal expansion valve 
+ Emerson electronic expansion valve.
RefrigerantR404AR404A+R23 Mixed refrigerant
High temperature coolingCan satisfy 150 degree direct start compressor cooling.
Sight window200×300200×300300×400200×300200×300300×400
Instrument connectionLeftφ50Leftφ50Lefφ100Leftφ50Leftφ50Leftφ100
Heat preservationPolyurethane foam + ultra fine glass fiber.
Liner materialSUS304 Stainless steel plate
Shell materialCold rolled plate spray
Inner dimension mm650*600*760800*735*8001000*1000*1000600*650*760800*735*8001000*1000*1000
Dimensions mm950×1100×18601100×1250×19001300×1500×2150950×1100×18601100×1250×19001300×1500×2150
Weight280kg390kg620kg320kg420kg680kg
Power380V3.8kw6.5kw9.5kw5kw8.5kw12kw
Standard Accessorias1 copy of product specification, 2 pieces of test stand, 1 piece of silicone rubber.;
Optional220V 60HZ three-phase, 460V 60HZ three-phase
OptionalOptional: wider range of temperature, minimum temperature to -150 degrees, maximum 
temperature to 300 degrees.
OptionalOptional cooling method for water cooling (low noise, good cooling effect)
OptionalExplosion-proof type is optional.