Wednesday, June 13, 2018

3 Box Type Cold And HotChamber

3 Box Type Cold And HotChamber


Applied range:

Three box is hot and cold impact test box according to user requirements design and manufacture, is suitable for the aviation, aerospace, military industry, ships, electrical and electronic products such as the machine and parts of high and low temperature impact test and high temperature or low temperature storage and test environment.For the user to accelerate the test of the whole machine (or parts), electrical apparatus, instrument, material, coating, coating and so on, so as to evaluate the test behavior of the test product or test.

 Performance characteristics:

1. The equipment is divided into high temperature box, low temperature box, test box of three parts, adopt unique thermal structures and heat storage effect, perfectly still, the object under test in testing the application of cold and hot wind path switching to cold, hot hot and cold impact test temperature import test area.
2. Use the most advanced measuring device, large color LCD controller USES a human-machine touch dialog type LCD human-machine interface controller, the operation is simple, learning easy, stable and reliable, the English display the complete system operation conditions, implement and setting process curve.
3. 96 independent setting test specification, impact time 999 hours 59 minutes, cycle 1 ~ 999 times can be set, which can realize automatic machine operation, the maximum extent, automation, reduce workload, operating personnel can be run automatically start and stop work at any time;
4. A 50mm diameter test hole is provided on the left side of the box, which can be used to test parts of power load wiring.
5. Can the independent set high temperature, low temperature and hot and cold impact the function of three different conditions, and perform in cold and hot shock condition, can choose two slot or three slot and cold shock, thermal shock impact function, has the function of the high and low temperature testing machine.
6. Fully automatic, high-precision system circuit, any movement of any machine, complete with P.L.C lock processing, all adopt P.I.D automatic calculation control, and the temperature control precision is high.
7. Advanced scientific air circulation design, keeping indoor temperature even and avoiding any dead Angle;Complete safety protection device, avoid any potential safety hazard, ensure the long-term reliability of the equipment.
8. Set cycle times and defrost times automatically (manual) defrost.The air outlet is controlled by the return air taste detector. The switch time of the damper is completed within 10 seconds, and the temperature recovery time of the cold and heat shock is completed within 3 minutes.
9. Operation state display and curve shows that an exception occurs, the screen instantly automatic display fault point and the reasons and provide troubleshooting methods, and found that the input power is not stable, with emergency stop device.
10. Refrigeration system using the cascade efficient cryogenic loop system design, refrigerating set by Europe and the United States imported compressor, and the use of ozone coefficient is zero (HFC) of green environmental protection refrigerants R507 R2 mixed refrigerants.
11. Super safe protection function: power overload protection, leakage protection, control circuit overload, short circuit protection, compressor protection, grounding protection, overtemperature protection, alarm sound warning, etc.
12. The inner and outer material of the box is made of stainless steel plate (SUS#304). The external material has a different outer box material to choose from :GB/T2423.1.2-2001, GJB150.5 GB10592-89.

 Technical parameters:

Model
CJS-12565W
CJS-21065W
CJS-50065W
CJS-100065W
Temp. range of cold and heat.
-70℃~200℃
-70℃~200℃
-70℃~200℃
-70℃~200℃
Shock Temp. Range
-60℃~160℃
-60℃~160℃
-60℃~160℃
-60℃~160℃
Cavity size
500×500×500
600×600×600
800×800×800
1000×1000×1000
Heating Power
5.5kw
7.5kw
10kw
15kw
Stable temp. fluctuation
±0.5℃
Temp.uniformity
±2℃
Temp.deviation
±2℃(Normal pressure, No load)
Conversion time
10S
Recovery Time
3min
Controller
Siemens PLC controller, Siemens color LCD touch screen.
Accuracy range
Setting accuracy: temperature 0.01K, indicating accuracy: temperature 0.01K
Temp.Sensor
Platinum resistance PT100Ω/MV
Heater
Fully independent system, stainless steel flange pipe heater.
System internal evaporator
RVCES
Evaporator
RVCES
Circulation pump
Guanya Magnetic Circulation Pump
Coolant
KDOC-70 Thermal conductive silicone oil
Compressor
France Taikang
Italy Dorin
Italy Dorin
Italy Dorin
Condenser
Paris/Shen's Tube Heat Exchanger

Cooling method
Water cooled

Cooling water 25 degrees
1200L/h 2bar
1500L/h 2bar
3000L/h 2bar
4800L/h 2bar
Circulatory system
Temperature and low noise air conditioning motor. Multi-leaf centrifugal wind wheel
Carton material
Quality carbon steel plate. Phosphating electrostatic spray treatment / SUS304 stainless steel matte line hairline processing
Inner box material
SUS304
Insulation material
Polyurethane rigid foam/ultrafine glass fiber cotton
Door frame insulation
Double layer high and low temperature aging silicone rubber door sealing strip.
Safety protection
Leakage, short circuit, over temperature, motor overheat, overload, over current protection Self-diagnosis function; Freezer overload protection; High pressure switch, lack of cooling water protection and other security features
Power 380V 50HZ
12KW MAX
16kw MAX
24KW MAX
36kw  max