Water Cooled Chiller Plant LD -80℃~-30℃



    Water Cooled Chiller Plant LD -80℃~-30℃



    -80℃~-30℃

     Technical Parameters:

    Medium-sized low-temperature freezer, the water cooled chiller plant has a temperature range from -80 ℃ ~ -30℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.

    Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.

    ModelLD-4WLD-6WLD-8WLD-12WLD-20WLD-30WLD-40WLD-60WLD-90WLD-120WLD-180W
    Temp. range-80°C~ -30°C
    Cooling capacity6kw9kw12kw18kw30kw45kw6090kw135kw180kw270kw
    At -60°C Kcal/h51607740103201548025800387005160077400116100154800232200
    Cooling capacity4kw6kw8kw12kw20kw30kw40kw60kw90kw120kw180kw
    At -75°C Kcal/h344051606880103201720025800344005160077400103200154800
    Circulation pump6.6m³/h6.6m³/h9m³/h15m³/h25m³/h25m³/h25m³/h35m³/h35m³/h50m³/h65m³/h
    2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar
    Connection sizeDN-25
    PN-10
    DN-25
    PN-10
    DN-32
    PN-10
    DN-32
    PN-10
    DN-40
    PN-10
    DN-40
    PN-10
    DN-40
    PN-10
    DN-50
    PN-10
    DN-50
    PN-10
    DN-65
    PN-10
    DN-65
    PN-10
    Cooling water
    30 DEG
    10m³/h14m³/h20m³/h25m³/h35m³/h45m³/h65m³/h90m³/h120m³/h180m³/h250m³/h
    Cool storage 
    tank (optional)
    200L350L500L750L1000L1200L1500L2200L3000L4000L5000L
    Expansion tank
    (optional)
    100L175L250L350L500L600L750L1000L1350L1800L2200L
    CompressorStandard: Dorin semi-closed compressorStandard: Hanbell screw compressor
    Optional: Bitzer screw compressor
    Operation panel7 inch color touch screen display input, temperature curve record.
    Control systemStandard: single chip microcomputer controller, position setting to open refrigeration
    and close refrigeration temperature difference.
    Optional: Siemens S7 series PLC and module.
    Circulation systemThe whole system is fully closed system. The heat conduction medium does not absorb
    the water in the air and will be replenished automatically at low temperature. The system
    will not increase the pressure due to the high temperature in the operation.
    Circulation pumpWuxi guanya tube type centrifugal pump.
    EvaporatorStandard: Brazing plate heat exchanger.
    Optional: stainless steel tube heat exchanger.
    CondenserShell and tube type water cooled condenser.
    Intermediate heat
    exchanger
    Plate heat exchanger.
    Drying filterEmerson
    Dry filter elementEmerson
    Expansion valveEmerson
    Refrigeration
    solenoid valve
    Emerson
    Oil separatorEmerson
    Pressure protectorEmerson
    Sight glassesStandard: Sanhua  Optional: Danfoss
    Refrigeration
    ball valve
    Schneider electric contact, schneider intermediate relay.
    ElectricityR404A
    RefrigerantStandard: Sanhua  Optional: Danfoss
    SecondaryrefrigerantEthanol, dichloromethane, heat conduction medium, etc.
    Security and
    protection
    High pressure protection, water break protection, current protection, leakage protection, 
    continuous and broken phase protection, high temperature protection, sensor fault alarm, 
    low level alarm and other multiple security protection.
    Level indicatorGlass level indication.
    Piping materialSUS304
    Expansion
    tank volume
    SUS304
    Shell materialChannel steel + square pipe + cold rolled steel
    Dimension cm205*145
    *175
    205*145
    *175
    205*145
    *175
    235*145
    *175
    235*145
    *175
    350*150
    *205
    350*150
    *205
    400*180
    *205
    450*200
    *205
    450*200
    *205
    650*220
    *235
    Power supply
    (max)
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    14kw18kw30kw43kw69kw101kw101kw200kw295kw396kw588kw
    NoiseWithin 75dbWithin 80dbWithin 90db
    Weight950kg1100kg1400kg1800kg2200kg3000kg3500kg4000kg5000kg6000kg8000kg

    Maintenance for Lubrication System of Water Cooled Chiller Plant
    When the chiller is below 80 ℃ ~ 30 ℃ below zero in the running system, people pay more attention to refrigerator, frozen water cycle system and electric control system, so the lubrication system is often overlooked. However, this system is also very important to the chiller. The maintenance of the chiller is indispensable, now we are going to tell you something about it.

    1. Observe the normal oil surface, oil temperature and oil pressure in the daily inspection.

    2. Regularly check the oil quality according to the oil change index stipulated in the frozen lubricating oil, and replace or supplement the filtered new oil.

    3. Pay attention to check and adjust the end face clearance of the oil pump in the middle and overhaul, and replace the pump when necessary. The end face clearance of the pump varies from 0.03 to 0.08mm. Please refer to the assembly technical requirements and factory regulations of the pump for concrete value.

    4. Regularly replace or clean the filter core, pipeline, and crankcase.

    The maintenance of the lubrication system of the chiller requires techniques, which mainly involves the performance of the compressor's main engine. It is recommended to be operated by professionals to avoid unnecessary losses.



    Contact Lneya for more.