Liquid Nitrogen Thermal Shock Test Chamber
Application:
Liquid nitrogen cooling and heat shock test chamber is suitable for electronic elements of safety performance test screening tests provide reliability test, products, etc., at the same time, through this equipment test, can improve the reliability of products and product quality control.
Box structure:
Hot and cold impact test box all functions controlled by computer, is a self-developed software, has the good interface, the user's operation and monitoring is more simple and intuitive, maintain function will keep you running applications in the present condition, can temporarily change the program of numerical, time parameters can be set on the screen, the refrigeration, heating and blue transfer switch, according to the set value automatically.
Independent control of cold box and hot box.
The liquid cabinet adopts vacuum heat preservation to ensure no leakage.
The product insulation effect can be fully guaranteed.
The test box door and the circulating fan, the blue transmission and other interlocks, protect the safety of the operator, once the door is opened, the circulation fan and the blue transmission power supply will be automatically cut off.
parameter:
type
|
CJN-20N2W
|
CJN-50N2W
|
CJN-80N2W
| |||
capacity
|
20L
|
50L
|
80L
| |||
parameter
|
High temp room
|
Expose temp range
|
+60℃~+200℃
| |||
Highest temp.
|
200℃(+200℃)
| |||||
Heating up time
|
+20℃~+200℃,20min
| |||||
Low temp room
|
Expose temp range
|
-196℃
| ||||
Lowest temp
|
-196℃
| |||||
Liquid nitrogen injection3L/min
| ||||||
bucket
|
Shock temp.
|
LT-196℃;HT+60~+150℃
| ||||
temperature fluctuation
|
≤±0.5℃
| |||||
temperature departure
|
≤±2℃
| |||||
Transfer time
|
≤15S
| |||||
Temp recovery time
|
≤5min
| |||||
Load (aluminum ingot)(kg)
|
5
|
7
|
15
| |||
box structure
|
cover
|
The surface of galvanized steel sheet is sprayed.
| ||||
liner
|
stainless steel plate
| |||||
thermal insulationmaterial
|
Low temperature (vacuum insulation + polyurethane foam board), high temperature (ultra-fine glass fiber)
| |||||
heater
|
Nichrome heater
| |||||
Bucket up and down
|
precision ball screw
| |||||
Test hole
|
1个,φ50,top of the case
| |||||
Temp sensor
|
pt100
| |||||
controller
|
Siemens Smart PLC controller/touch screen.
| |||||
Data record
|
USB disk
| |||||
communication
|
RS485interfaceModbus RTUprotocol
| |||||
Bucket dimension(mm)
|
D
|
260
|
400
|
450
| ||
W
|
260
|
400
|
450
| |||
H
|
300
|
350
|
400
| |||
Body dimension(mm)
|
D
|
1100
|
1250
|
1300
| ||
W
|
1000
|
1150
|
1200
| |||
H
|
1900
|
2000
|
2000
| |||
Installed power
|
2kw
|
3kw
|
4kw
| |||
POWER
|
AC220V 50Hz
| |||||
standard
|
GJB360.7、GB/T2423.22、GB/T2423.1.2、GB10592-2008、GJB150.3
|