Water Cooled Industrial Chiller LJ -45℃~-10℃

Water Cooled Industrial Chiller LJ -45℃~-10℃



-45℃~-10℃

 Technical Parameters:

Water cooled industrial chiller: Medium-sized low-temperature freezer, refrigeration temperature range from -45 ℃ ~ -10℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.direct-cooled ultra-low temperature freezer, low-temperature freezer, industrial freezer, ultra-low temperature cooling equipment, freezer, industrial low-temperature freezer.
ModelLJ-6WLJ-10WLJ-15WLJ-20WLJ-30WLJ-40WLJ-60WLJ-90WLJ-120WLJ-180W
Temp. range-45°C~ -10°C
Cooling capacity12kw20kw30kw40kw60kw80kw120kw180kw240kw360kw
At -20°C Kcal/h103201720025800344005160068800103200154800206400309600
Cooling capacity6kw10kw15kw20kw30kw40kw60kw90kw120kw180kw
At -40°C Kcal/h516086001290017200258003440005160077400103200154800
Circulation pump6.6m³/h9m³/h15m³/h15m³/h25m³/h25m³/h25m³/h35m³/h35m³/h50m³/h
2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar
Connection sizeDN-25
PN-10
DN-25
PN-10
DN-32
PN-10
DN-32
PN-10
DN-40
PN-10
DN-40
PN-10
DN-40
PN-10
DN-50
PN-10
DN-50
PN-10
DN-65
PN-10
Cooling water 30℃8m³/h10m³/h16m³/h20m³/h25m³/h30m³/h38m³/h55m³/h70m³/h100m³/h
Cool storage tank (optional)200L350L500L750L1000L1200L1500L2200L3000L4000L
Expansion tank (optional)100L175L250L350L500L600L750L1000L1350L1800L
CompressorStandard: Dorin semi-closed compressor
Standard: Hanbell screw compressor
Optional: Bitzer screw compressor
Operation panel7 inch color touch screen display input, temperature curve record.
Control systemStandard: single chip microcomputer controller, position setting to open refrigeration
and close refrigeration temperature difference.
Optional: Siemens S7 series PLC and module.
Circulation systemThe whole system is fully closed system. The heat conduction medium does not absorb
the water in the air and will be replenished automatically at low temperature. The system
will not increase the pressure due to the high temperature in the operation.
Circulation pumpWuxi guanya tube type centrifugal pump.
EvaporatorStandard: Brazing plate heat exchanger.
Optional: stainless steel tube heat exchanger.
CondenserShell and tube type water cooled condenser.
Intermediate heat exchangerPlate heat exchanger.
Drying filterEmerson
Dry filter elementEmerson
Expansion valveEmerson
Refrigeration solenoid valveEmerson
Oil separatorEmerson
Pressure protectorEmerson
ReservoirStandard: Ruishipu             Optional: Emerson
Sight glassesStandard: Sanhua  Optional: Danfoss
Refrigeration ball valveStandard: Sanhua  Optional: Danfoss
ElectricitySchneider electric contact, schneider intermediate relay.
RefrigerantR404A
SecondaryrefrigerantNon-corrosive liquid, ethanol aqueous solution, thermal conductivity oil, etc.
Security and protectionHigh pressure protection, water break protection, current protection, leakage protection,
continuous and broken phase protection, high temperature protection, sensor fault alarm,
low level alarm and other multiple security protection.
Level indicatorGlass level indication.
Piping materialSUS304
Expansion tank volumeSUS304
Shell materialChannel steel + square pipe + cold rolled steel
Dimension cm160*100
*165
180*120
*175
180*120
*175
205*145
*175
205*145
*175
235*145
*175
245*145
*205
350*150
*205
350*150
*205
450*200
*205
Power supply380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
10kw14kw22kw31kw45kw61kw86kw127kw167kw247kw
NoiseWithin 75dbWithin 80dbWithin 90db
Weight800kg950kg1100kg1350kg1500kg1800kg2400kg3100kg3600kg5000kg
Tips for Removing Fouling of Water Cooled Industrial Chiller
During the process of production in factory, many chillers wok under the temperature of subzero 45 to zero, and their inner tube wall of condenser is easily fouled, which will affect the heat transfer effect and increase the condensing temperature of  the chillers, and then reduce the cooling capacity and increase the power consumption. So how can we clean it?

1. Close valve of the condenser for the entry of cooling water, use the thermometer tube, the pressure gauge tube or the drain pipe to connect the anticorrosion pump and the dispensing tank to make a small circulation system and clean it in recycle.

2. Add the pickling inhibitor first, which is a special copper corrosion inhibitor. It adheres to the inner wall of the condenser and prevents acid reacted with metal.

3. Add solid acid washing agent, which is used to clean the fouling with the main component of calcium carbonate. The agent is a compound solid organic acid, white crystal, no corrosion to metal, weak acid, and the dosage is determined by the fouling degree of equipment.

4. Add dirt stripping agent (optional), if the condenser equipment is thicker, add dirt stripping agent to promote the products of fouling reaction to quickly dissolve in water and accelerate reaction.

5. Add neutralization passivator, after chemical cleaning of the condenser, neutralizing residual acid to prevent oxidation of metal surface and generate floating rust.

Contact Lneya for more.