Ultra Low Lab Freezer DW -30℃~-86℃
Information: Ultra low lab freezer is widely used in blood stations, hospitals, health, and epidemic prevention departments, research institutes, electronics industry, chemical medicine, biological engineering, laboratory, military industrial enterprises etc.
Model | DW-8L158S | DW-8L398S | DW-8W598S | DW-8W930S | DW-8W58S | DW-8W118S | DW-8W258S | DW-8W458S |
Temp.range | -30℃~-86℃ | |||||||
Inner volume | 158L | 398L | 598L | 930L | 58L | 118L | 258L | 458L |
Inner dimension (mm) | 460*455 *800 | 550*630 *1140 | 780*680 *1255 | 1000*700 *1335 | 410*410 *355 | 500*400 *560 | 780*500 *600 | 1380*500 *660 |
Input power | 650W | 700W | 1200W | 500W | 650W | 700W | ||
Inner doors | 2 | 3 | 3 | 4 | None | |||
Type | Vertical | Chest type | ||||||
Compressor | SECOP system compressor | |||||||
Fan | EBM | |||||||
Refrigeration technology | Using single compressor cascade technology, simple structure, low energy consumption, low failure rate | |||||||
Refrigerant | Using single compressor cascade technology, simple structure, low energy consumption, low failure rate | |||||||
Control system | LNEYA control system | |||||||
Display | 7- inch color touch screen | |||||||
Temp. record | Real-time curve records of tank, ambient and set temperature, 18 months curve record, export to U disk ( in EXCEL format) | |||||||
Lock | Standard equipped with electromagnetic lock and a padlock hole | |||||||
Doors open records | Can allocate 6 group authorization, each group with independent user name and password, to ensure that each time it can record the user name and time of opening doors. | |||||||
Dimension(mm) | 770*700 *1500 | 920*930 *1990 | 1020*950 *2050 | 1300*1000 *2150 | 7450*760 *1080 | 1350*780 *1050 | 1600*890 *1100 | 2200*890 *1150 |
Power | 220V 50HZ/ 230V 60HZ | |||||||
Noise | 58db | |||||||
Material | Inner SUS304, cold rolled steel case | |||||||
Climate type | Natural | |||||||
UPS | Standard machine with 24V 12AH control system spare power | |||||||
Safety Protection | High and low pressure protection and display, Electric leakage protection, Power outage alarm, ambient temperature monitoring, sensor fault alarm,control system UPS power |
In order to achieve the long-term use of low temperature chest freezer minus 30 DEG ~-86 DEG and prolong its life, we need to pay attention while using. Today Guanya will tell something about it and hope them be helpful for you.
1. The indoor temperature should not be too high, it is better to put in the air-conditioned room. Always pay attention to the indoor voltage, keep it stable.
2. Reduce the times of opening the door. Once the sample is not too much. It is suggested that it should be put in batch and classified if the specimen is large.
3. Do not open the door to find things. Take the sample quickly and determinedly.
4. Regular defrosting is also essential.
5. According to the sample storage temperature demand, set the corresponding temperature. When the sample storage temperature needn't to be-86 degrees.It is not recommended to set the temperature to -86 degrees because this makes the ultra-low temperature refrigerator tired and costly.
Contact Lneya for more.
1. The indoor temperature should not be too high, it is better to put in the air-conditioned room. Always pay attention to the indoor voltage, keep it stable.
2. Reduce the times of opening the door. Once the sample is not too much. It is suggested that it should be put in batch and classified if the specimen is large.
3. Do not open the door to find things. Take the sample quickly and determinedly.
4. Regular defrosting is also essential.
5. According to the sample storage temperature demand, set the corresponding temperature. When the sample storage temperature needn't to be-86 degrees.It is not recommended to set the temperature to -86 degrees because this makes the ultra-low temperature refrigerator tired and costly.
Contact Lneya for more.
No comments: