Cryo Refrigeration -65℃~-10℃
Overview:
- Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1℃, inside the temperature range -20 ℃ ~ -125 ℃ adjustable.
- Multi-safety protection, more reliable operation.
- France TECUMSEH compressor, Germany DANFOSS compressor, EMERSON compressor, automatic cascade refrigeration technology.
- With self-diagnosis function, freezer overload protection, high-pressure switches, overload relays, thermal protection device and other security functions, and fully guarantee the use of safety.
- Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer, the effect of good insulation; Inline vacuum insulation panels.
- Human design, more convenient and flexible.
- Suitable for mechanical producing plant use, lab refrigerator.
Technical Parameters:
Model
|
GX-6528N
|
GX-6550N
|
GX-6580N
|
GY-6528N
|
GY-6550N
|
GY-6580N
|
GY-65A16N
|
volume
|
280L
|
500L
|
800L
|
280L
|
500L
|
800L
|
1600L
|
Inner dimension
|
610*600*760
|
800*735*850
|
1000*800*1000
|
800*600*600
|
1200*650*650
|
1350*800*750
|
2000*900*900
|
Type
|
(Vertical)
|
(Chest/Horizontal)
| |||||
Capacibility carrying
|
150KG
|
220KG
|
300KG
|
150KG
|
220KG
|
300KG
|
650KG
|
Designed bearing capacity is two times of the standard one, (refrigeration system is designed according to the standard capacity when target artifact weight is greater than the standard capacity, the cooling rate will decrease)
| |||||||
Temp. range
|
-65℃~60℃
|
-65℃~60℃
|
-65℃~60℃
|
-65℃~60℃
|
-65℃~60℃
|
-65℃~60℃
|
-65℃~60℃
|
Cooling capacity at -60℃
|
1kw
|
1.5kw
|
2.5kw
|
1kw
|
1.5kw
|
2.5kw
|
4kw
|
Temp. accuracy
|
±2℃
|
±2℃
|
±2℃
|
±2℃
|
±2℃
|
±2℃
|
±2℃
|
Heating power
|
2kw
|
3kw
|
5kw
|
2kw
|
3kw
|
5kw
|
8kw
|
Nickel-chromium alloy electric heating heater, the controller has double safety protection, with independent temperature limiter protection.
| |||||||
Cooling rate
|
(ambient temperature of 25 degrees, no-load, from 60 degrees to -60 degrees about 1 hour).;cooling rate will be a little different for temperature changes.
| ||||||
Controller
|
ASET multifunctional controller
| ||||||
Operation panel
|
7-inch color touch screen, display set temperature, measured temperature.
| ||||||
Temp. record
|
Temperature curve and fault record, U-disk data export, excel format.
| ||||||
Inside circulating air
|
1650 m³/h
|
2100 m³/h
|
2750 m³/h
|
2100 m³/h
|
2750 m³/h
|
3500 m³/h
|
6000 m³/h
|
When it is open, the internal circulation fan automatically turns off. The touchscreen displays open state.
| |||||||
Compressor
|
Emerson Copeland, adopt cascade refrigeration technology
| ||||||
Intermediate heat exchanger
|
KAORI Plate heat exchanger
| ||||||
Dry filter
|
Emerson
| ||||||
Expansion valve
|
Electronic expansion valve
| ||||||
Evaporator
|
Copper-tube with aluminum-fin
| ||||||
Cooling Type
|
Air-cooled with water-cooled auxiliary functions (Ensure good cooling capacity when temp. above 30 degrees)
| ||||||
Means of insulation
|
Polyurethane foam insulation, thermal insulation layer 125 mm, with embedded FIR boards
| ||||||
Safety Protection
|
Self-diagnosis function; Phase sequence phase failure protection; leakage protector; cooling unit overload protection; high and low pressure switch, overload relay, thermal protection device, high temperature protection and temperature fault protection.
| ||||||
Case material
|
Outside is cold rolled steel painting, internal is SUS304 wire drawing board.
| ||||||
Refrigerant
|
R404A R23
| ||||||
Dimension
|
1150*1150*1850
|
1350*1300*1850
|
1550*1300*2100
|
2200*1150*1150
|
2700*1200*1200
|
2900*1300*1250
|
3700*1400*1350
|
Power 380V 50HZ
|
5.5KW MAX
|
7.5KW MAX
|
13.5KW MAX
|
5.5KW MAX
|
7.5KW MAX
|
13.5KW MAX
|
19KW MAX
|
Weight
|
380kg
|
480kg
|
650kg
|
385kg
|
485kg
|
650kg
|
780kg
|
Optional
|
High temperature reaches 150degree and temperature accuracy is ±0.5degree;the input power will be changed(When select this model, the thickness of thermal insulation layer will be 150mm,thermal insulation material will be silicate and vacuum plate)
| ||||||
Optional
|
Closed circulating oil heating system, no direct electric heating element inside the box, suitable for flammable products test
| ||||||
Optional
|
Temp. accuracy ±0.5℃
| ||||||
Optional
|
Cooling and heating program controlled, meet cold treatment process requirements(can set 5 programs, each program can edit 45 steps.)
| ||||||
Optional
|
Interior door, reduce cooling capacity lost when picking small workpieces (temperature below 60 degrees optional)
| ||||||
Optional
|
Outside SUS304 wire drawing board case
| ||||||
Optional
|
Diameter 50mm cable hole
| ||||||
Optional
|
Electric heating vacuum glass observation window (with lighting) 200mm*300mm
| ||||||
Optional
|
Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently)
|
Ultra-low temperature refrigerator is also known as cryopreservation box, cryogenic refrigerator, cryopreservation box, cryo refrigeration and so on, the common low temperature refrigerator of which is -65 ℃ ~ -10℃.
The cryogenic systems of ultra-low temperature refrigerator basically adopts the working principle of cascade refrigeration and is equipped with two fully enclosed compressors as high and low temperature compressor. The copper tube of the low-temperature evaporator is attached directly to the outside of the inner box in the form of a coil and with heat transfer cement block between the coil and the box wall of the gap, to increase the heat exchange effect. The condensing evaporator is a shell tube structure with four tubes of the thread-shaped copper tube and a countercurrent heat exchange.
The cryogenic stage system is equipped with a gas heat exchanger to make the low-pressure gas coming out of the evaporator heat exchange with the high-pressure gas before the condenser-evaporator, which not only reduces the heat load of the condensing evaporator but also makes full use of the heat.The wax removal filter is the most common, the main purpose of the filter is to remove the paraffin from the frozen oil in order to reduce the possibility of "oil plugging" in the system.
In addition, according to different applications, ultra-low temperature refrigerator can also be equipped with some accessories. For example, take temperature re
corder for a permanent record of operating parameters; use the carbon dioxide backup system for special circumstances to ensure the gas preservation environment to maintain a normal state and choose the voltage booster for guaranteeing the normal work of the compressor under low pressure.
Contact Lneya for more.
The cryogenic systems of ultra-low temperature refrigerator basically adopts the working principle of cascade refrigeration and is equipped with two fully enclosed compressors as high and low temperature compressor. The copper tube of the low-temperature evaporator is attached directly to the outside of the inner box in the form of a coil and with heat transfer cement block between the coil and the box wall of the gap, to increase the heat exchange effect. The condensing evaporator is a shell tube structure with four tubes of the thread-shaped copper tube and a countercurrent heat exchange.
The cryogenic stage system is equipped with a gas heat exchanger to make the low-pressure gas coming out of the evaporator heat exchange with the high-pressure gas before the condenser-evaporator, which not only reduces the heat load of the condensing evaporator but also makes full use of the heat.The wax removal filter is the most common, the main purpose of the filter is to remove the paraffin from the frozen oil in order to reduce the possibility of "oil plugging" in the system.
In addition, according to different applications, ultra-low temperature refrigerator can also be equipped with some accessories. For example, take temperature re
corder for a permanent record of operating parameters; use the carbon dioxide backup system for special circumstances to ensure the gas preservation environment to maintain a normal state and choose the voltage booster for guaranteeing the normal work of the compressor under low pressure.
Contact Lneya for more.