High-Low Temp. Humidity Test Chamber

High-Low Temp. Humidity Test Chamber


Temperature range
(-40℃、-70℃)~ +100℃
Humidity range
25%R.H ~95%R.H
Temperature fluctuation
±0.5℃
Rate of rise and fall
0.5℃/min~10℃/min

Volume
Studio size
Outside size
Overall dimensions of the machine
The gate size
6m3
1600×1800×2000
1950×2550×2380
1950×(3150~3750)×2380
1000×2000
8m3
2000×2000×2000
2350×2750×2380
2350×(3350~3950)×2380
1000×2000
10m3
2000×2500×2000
2350×3250×2380
2350×(3850~4450)×2380
1000×2000
11m3
2800×2000×2000
3150×2750×2380
3150×(3350~3950)×2380
1000×2000
12m3
3000×2000×2000
3350×2750×2380
3350×(3350~3950)×2380
1000×2000
14m3
2700×2300×2300
3050×3050×2680
3050×(3650~4250)×2650
1000×2000
16m3
4000×2000×2000
4350×2750×2380
4350×(3350~3950)×2380
1000×2000
20m3
3000×3000×2200
3350×3750×2580
3350×(4350~4950)×2580
1600×2000
24m3
3000×2500×2500
3350×3250×2880
3350×(3850~4450)×2880
1600×2000
29m3
3000×3200×3000
3350×3950×3380
3350×(4550~5150)×3380
1600×2000
32m3
4200×3200×2200
4550×3950×2580
4550×(4550~5150)×2580
2000×2000
36m3
4000×3000×3000
4350×3750×3380
4350×(4350~4950)×3380
2000×2500
40m3
3600×4400×2500
3950×5150×2880
3950×(5750~6350)×2880
2000×2500
66m3
4200×8000×2000
4550×8750×2380
4550×(9350~10250)×2380
3000×2000

Performance characteristics:

1. It has wide temperature control range, which can meet the needs of users.
2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control can be carried out;The temperature is displayed by touch screen, easy to read, precise and convenient.
3. The temperature error can be adjusted to meet your more accurate test conditions.
4. It has the function of automatically selecting the running refrigeration circuit with the setting of temperature, and the operation is simple.
5. The box door is equipped with a large observation window, which can observe the test status of the test sample at any time.
6. with functions of high temperature on, can be in when the temperature in the oven to 100 ℃, can open the refrigerator, facilitate continuous round-trip experiment was carried out between the high temperature and low temperature.
7. It has the functions of self-diagnosis, overload protection of refrigerator, high pressure switch, overload relay, thermal protection device, etc., to ensure the safety of use.
8. Use a multi-wing fan to circulate the wind in a strong way to avoid any dead Angle, so that the temperature can be evenly distributed in the test area.
9. Wind circulation is designed with wind return wind. The wind pressure and wind speed are in accordance with the test standard.
10. Temperature rise, cooling and system complete independence can improve efficiency, reduce test cost, increase life span and reduce failure rate.
11. The water tank is placed on the side of the unit, and there is water shortage and automatic protection, so as to facilitate the operator to replenish the water supply.
12. The humidification system pipeline is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline and improve the safety.
13. The system of waterway system is opened by door, which is convenient for maintenance and maintenance.
14. In refrigeration system, air cooling or water cooling is adopted in condensation.