Compared with other types of chillers, the overall energy consumption of high-quality screw water chiller is relatively small. Because the production technology of screw water chiller is more advanced and less energy is used, the equipment can quickly realize the purpose of reducing space temperature. The more screw water chillers are used in enterprises, the stronger the ability to reduce space temperature per unit time is, thus providing conditions for enterprises to reduce energy consumption costs. The longer the enterprises use screw water chillers, the less energy they consume as a whole.
Because screw water chillers are designed and manufactured with advanced production technology, the overall failure rate is low. Even if the screw water chiller is used uninterruptedly for a long time, the screw water chiller will not have more faults. The fewer faults the screw chiller produces, the higher the safety factor of the enterprise using the screw water chiller, so as to provide technical guarantee for prolonging the service life of the equipment.
Although the cooling performance of screw water chiller is very high, there are still many potential safety hazards when using screw water chillers. Because screw water chillers use more accessories, if a single component fails, it will threaten the normal operation of the equipment, and even lead to irreparable failure of the equipment. When enterprises use screw water chillers, they must be carefully tested to prevent all kinds of faults, so as to ensure that the long-term uninterrupted operation of screw chillers will not have any faults.
How to prevent malfunction? If the screw water chiller fails many times, it will threaten the safety of the equipment. Before using the screw water chiller, it is necessary to carry out a comprehensive inspection of the equipment regularly, which can detect and deal with all kinds of faults in time, so as to prolong the service life of the equipment and help enterprises reduce the space temperature in the shortest time.
Showing posts with label air cooling system. Show all posts
Showing posts with label air cooling system. Show all posts
Sunday, July 21, 2019
Monday, June 4, 2018
Recirculating Air Control System
Recirculating Air Control System
Description & Application:
1. Widely used in the semiconductor device for testing high and low temperature.
2. Independent refrigerated air recirculating unit.
3. Can work for a long time continuously, defrosting automatically and it can not affect the storage temperature in the process of defrosting.
4. Modular design and replace easily for standby machine,(If there are 10 sets of machines, only one standby machine is enough).
5. Solve the problems of open or close the door frequently and frosting problem in evaporation system, it will not affect the temperature of the cold storage&cryogenic box in the process of defrosting in evaporation system.
6. Easy installation (joint the box according to mechanical drawing, connect the electricity and water and set temperature completely to work).
2. Independent refrigerated air recirculating unit.
3. Can work for a long time continuously, defrosting automatically and it can not affect the storage temperature in the process of defrosting.
4. Modular design and replace easily for standby machine,(If there are 10 sets of machines, only one standby machine is enough).
5. Solve the problems of open or close the door frequently and frosting problem in evaporation system, it will not affect the temperature of the cold storage&cryogenic box in the process of defrosting in evaporation system.
6. Easy installation (joint the box according to mechanical drawing, connect the electricity and water and set temperature completely to work).
Technical Parameters:
Model
|
AI-635W
|
AI-655W
|
AI-6A10W
|
AI-835W
|
AI-805W
|
AI-810W
| |
Recirculating air temperature range ℃
|
-65℃~125℃
|
-65℃~125℃
|
-65℃~125℃
|
-85℃~125℃
|
-85℃~125℃
|
-85℃~125℃
| |
Control mode
|
PID adaptive controller
| ||||||
Communication protocol
|
MODBUS RTU Protocol, RS 485 Interface
| ||||||
Temperature feedback
|
PT100
| ||||||
Input & display
|
7-inch color touch screen controller, temperature curve record, data export to excel format.
| ||||||
Temp. accuracy
|
±0.2℃
| ||||||
Heating power
|
3.5kW
|
5.5kW
|
10kW
|
3.5kW
|
5.5kW
|
10kW
| |
Cooling capacity
|
125℃
|
3.5kW
|
5.5kW
|
10kW
|
3.5kW
|
5.5kW
|
10kW
|
50℃
|
3.5kW
|
5.5kW
|
10kW
|
3.5kW
|
5.5kW
|
10kW
| |
20℃
|
3.5kW
|
5.5kW
|
10kW
|
3.5kW
|
5.5kW
|
10kW
| |
0℃
|
3.5kW
|
5.5kW
|
10kW
|
3.5kW
|
5.5kW
|
10kW
| |
-20℃
|
3kW
|
4.2kW
|
7.8kW
|
3.5kW
|
5.5kW
|
10kW
| |
-40℃
|
2.1kW
|
3.2kW
|
4.6kW
|
2.5kW
|
3.9kW
|
7.1kW
| |
-55℃
|
0.8kW
|
1.2kW
|
2.2kW
|
1.6kW
|
2.4kW
|
4.2kW
| |
-75℃
|
0.9kW
|
1.3kW
|
2.2kW
| ||||
Circulating air flow
|
400m3/h
|
900m3/h
|
1300m3/h
|
400m3/h
|
900m3/h
|
1300m3/h
| |
Connection size(outlet/inlet air)
|
DN-100
|
DN-100
|
DN-125
|
DN-100
|
DN-100
|
DN-125
| |
Compressor
|
Scroll Copeland Compressor
| ||||||
Evaporator
|
Copper pipe aluminium fin (LNEYA)
| ||||||
Safety protection
|
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,
liquid low level protection, high temperature protection and temperature fault protection.
| ||||||
Defrosting device
|
There are installed defrosting device and condensate drain inside
| ||||||
Continuous work
|
Can work continuously
| ||||||
Timing on & off operation
|
Can set a key time for starting up & stop
| ||||||
Refrigerant
|
R404A R508B
|
R404A R508B
|
R404A R508B
|
R404A R508B
|
R404A R508B
|
R404A R508B
| |
Air pressure
|
4bar
|
5bar
|
5bar
|
4bar
|
5bar
|
5bar
| |
Water-cooled W (temp.20 degree)
|
1200L/H
1.5bar~4bar
|
1800L/H
1.5bar~4bar
|
3200L/H
1.5bar~4bar
|
1600L/H
1.5bar~4bar
|
2600L/H
1.5bar~4bar
|
3400L/H
1.5bar~4bar
| |
Product Dimension
|
650*750*1500
|
700*800*1650
|
700*800*1650
|
650*750*1500
|
700*800*1650
|
700*800*1650
| |
Weight (water cooled)
|
280kg
|
315kg
|
380kg
|
300kg
|
360kg
|
420kg
| |
Power
|
AC 380V 50HZ
7.5kW (max)
|
AC380V 50HZ
10.5kW (max)
|
AC 380V 50HZ
19kW (max)
|
AC380V50HZ
9kW (max)
|
AC380V50HZ
12kW (max)
|
AC380V50HZ
22kW (max)
| |
Case material
|
SUS 304
|
SUS 304
|
SUS 304
|
SUS 304
|
SUS304
|
SUS304
| |
How to clean air control system?
In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the air control systems, it is still necessary to have some knowledge of maintenance, and the most important thing to maintain is to say clean. Here, Guanya Refrigeration introduces some small methods for cleaning the air cooling system:More traditional methods are scraping and brushing. Sweep the place where you need to clean and the brush. The dirt that cannot be easily wiped off can be scraped with a sword. The second step is to use high-pressure water or chemical cleaning (mainly pickling), only to get high-pressure water or chemical water in the place where there is dirt to carry out chemical reactions, so that the dirt can be off.
However, this more traditional method does not generally clean thoroughly, and cleaning with chemical water may also cause corrosion to the equipment and damage the machine. After the chemical waste has been washed away, it will take a lot of money to process it. Therefore, cleaning agents can be used. This is also relatively environmentally friendly, safe, and thorough in cleaning. Generally, oxidation does not occur, which is beneficial to the service life of the air cooling system.
Contact Lneya for more.
Subscribe to:
Posts (Atom)



