Use high temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.
type
|
Temp range℃
|
Heating KW
|
Cooling capacity KW AT ℃
|
Flow/pressure
L/min bar |
Outside size
|
power
KW | ||||||
250
|
0
|
-40
|
-60
|
-80
|
-85
| |||||||
SUNDI-925W
|
-90~+250
|
2.5
|
2.5
|
2.5
|
2
|
1.1
|
0.35
|
0.2
|
20
|
1
|
550*680*1450
|
7.5kw
|
SUNDI-935W
|
-90~+250
|
3.5
|
3.5
|
3.5
|
2.8
|
1.9
|
0.5
|
0.3
|
35
|
2
|
650*700*1750
|
10kw
|
SUNDI-955W
|
-90~+250
|
5.5
|
5.5
|
5.5
|
5
|
2.8
|
0.8
|
0.5
|
50
|
2
|
750*800*1850
|
15kw
|
SUNDI-975W
|
-90~+250
|
7.5
|
7.5
|
7.5
|
6
|
3.2
|
1.2
|
0.7
|
75
|
2
|
750*800*1850
|
19kw
|
SUNDI-9A10W
|
-90~+250
|
10
|
10
|
10
|
8
|
4.2
|
1.6
|
0.85
|
110
|
2.5
|
1000*950*1750
|
24kw
|
SUNDI-9A15W
|
-90~+250
|
15
|
15
|
15
|
12
|
6
|
2.1
|
1.3
|
110
|
2.5
|
1500*1250*2050
|
35kw
|
SUNDI-9A25W
|
-90~+250
|
25
|
25
|
25
|
20
|
10
|
3.5
|
1.9
|
200
|
2.5
|
1500*1250*2050
|
50kw
|
SUNDI-9A38W
|
-90~+250
|
38
|
38
|
38
|
31
|
16
|
6
|
3.5
|
200
|
2.5
|
2050*1450*2050
|
74kw
|
SUNDI-9A60W
|
-90~+250
|
60
|
60
|
60
|
48
|
24
|
11
|
6
|
400
|
2.5
|
2450*1450*2250
|
115kw
|
SUNDI-9A80W
|
-90~+250
|
80
|
80
|
80
|
64
|
32
|
15
|
8
|
400
|
2.5
|
2750*1600*2250
|
165kw
|
Type
|
SUNDI/UST series
|
Control Mode
|
Feedback PID + Our special dynamic control calculation, Lneya PLC controller
|
Temp.control
|
Material reaction temp.control mode and jacket temp.control mode
|
Program Editor
|
10 programs, each program can edit 45 steps.
|
Communication Portocol
|
MODBUS RTU Protocol,RS485 interface
Optional Ethernet interface/R232 interface
|
Temp.feedback
|
The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
|
Material temp. feedback
|
Material temp. feedback:PT100 or 4~20mA or communication given
Temp.feedback:PT100
|
Temp. difference
|
Set or control oil outlet temp and reactor material temp. difference
Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)
|
Material temp.accuracy
|
±1℃ (sometimes ±0.5℃)
|
Thermal medium temp. accuracy
|
±0.5℃
|
Closed circulation system
|
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
|
heating
|
Heating max output power
The heater has triple protection and independent temperature limiter to ensure the safety of heating system.
The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.
|
Cooling capacity
|
The power of taking away the heat at different temperature
|
Circulation flow rate and pressure
|
Lower than 75L/min, use Lneya Magnetic pump
Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.
Pressure selection: 2bar 3bar 5bar 8bar(small power equipment can not customize)
The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.
|
compressor
|
Different type different brand compress
Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.
|
evaporator
|
KAORI Plate heat exchanger
|
Oil separator
|
Emerson/Lneya
|
Drying filter
|
danfoss/Emerson
|
Shock tube
|
CASTEL/packless
|
voltage-controlled
|
danfoss/Emerson/fengsheng
|
Expansion valve
|
Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Select different expansion valves with different temperature and cooling capacity.
|
Operation panel
|
Lneya 7-inch touch screen,show temp curve\EXCEL data output
Optional Siemens explosion - proof touch screen.(Place the operation panel outside the site area.)
optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)
|
Safety protection
|
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
|
refrigerant
|
R-404A / R404A R23 mixture/ R404A R23 R14 mixture
|
interface size
|
G1/2、G3/4、G1、DN25 DN32 DN40 DN50 DN65 DN80 DN100(PN10 RF)
|
Water-cooling W
|
With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water
|
Water cooled condenser.
|
Tube heat exchanger, plate heat exchanger, tube condenser.
packless、sheng、KAORI、JINDIAN、XIAOLING etc
|
power
|
AC 380V 50HZ Three-phase five-wire system. Small power 220V 50HZ single phase
Optional 460V 60HZ、220V 60HZ three-phase
|
Shell material
|
Standard shellSUS 304,optionalspraying plastics (color 7035)
|
Isolation of explosion-proof
|
optioanl(EXdIIBT4)
Lneya explosion-proof product installation license number.:PCEC-2017-B025
|
Positive pressure explosion-proof
|
optioanl(EXPXdmbIICT4) The positive pressure system must be water-cooled type
Lneya explosion-proof product installation license number:PCEC-2017-B025
|
Self pressurizing system
|
Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.
KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).
KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).
KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)
|
Flow/pressure
|
Optional flow/pressure sensor, display flow and pressure on the touch screen.
Optional control flow/pressure.
|
One for two system
|
Optional one for two systems: the costis lower than one to one system.
One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.
|
High exothermic control
|
Customizable high heat control system algorithm and components.
|
flow reactor temperature control module.
|
It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)
|
The Correct Use of the Refrigerant in the Temperature Control System
If the temperature control system has been used for more than six months, or the high and low pressure often fails, or the cooling capacity is reduced, please arrange the staff to clean the radiator.We all know that refrigerants are an essential material for the use of temperature control systems. Then do you know how much the refrigerant is suitable for the temperature control system in subzero 90 to 250?
When the temperature control system uses the pump filling machine to fill the refrigerant, it only needs to close the empty cut-off valve on the empty filling machine after the end of the pump, and the refrigerant can be filled to the refrigeration system by opening the filling valve. Under the certain amount of the filling in the cold water machine, neither too much nor too little, the small temperature control system use the quantitative filling device to fill the refrigerant by filling the refrigerant, it only needs to close the three valves after the vacuum of the refrigerating device and stop the vacuum pump, and dismantle the joint of the pressure resistant rubber tube connected with the vacuum pump and install it in the quantitative filling device. Open the liquid outlet valve and drain the air in the hose, then tighten the connector of the hose to check whether it leaks.
When the refrigerant of the temperature control system is filled with the refrigerant, read the pressure gauge on the filling device at the very first, the rotate the scale sleeve, and the quantitative liquid line corresponding to the pressure gauge is found on the sleeve, and the initial level of the liquid surface of the refrigerant in the glass tube is recorded. Then open the three-way valve, the refrigerant enters the refrigeration system through the hose, and the liquid level of the refrigerant in the glass tube begins to decrease. When the required amount of filling is achieved, close the discharge chamber and the three links on the charging device and the charging operation end.
The temperature control system is used in many fields. Plastic, electronic. Electroplate。 Laser, food, textile, chemical industry. Packing。 Medical care。 Even in industries such as test and even beverage, the industrial refrigeration equipment and temperature control system group play a very important role in beer production line.
If the temperature control system has been used for more than six months, or the high and low pressure often fails, or the cooling capacity is reduced, please arrange the staff to clean the radiator.We all know that refrigerants are an essential material for the use of temperature control systems. Then do you know how much the refrigerant is suitable for the temperature control system in subzero 90 to 250?
When the temperature control system uses the pump filling machine to fill the refrigerant, it only needs to close the empty cut-off valve on the empty filling machine after the end of the pump, and the refrigerant can be filled to the refrigeration system by opening the filling valve. Under the certain amount of the filling in the cold water machine, neither too much nor too little, the small temperature control system use the quantitative filling device to fill the refrigerant by filling the refrigerant, it only needs to close the three valves after the vacuum of the refrigerating device and stop the vacuum pump, and dismantle the joint of the pressure resistant rubber tube connected with the vacuum pump and install it in the quantitative filling device. Open the liquid outlet valve and drain the air in the hose, then tighten the connector of the hose to check whether it leaks.
When the refrigerant of the temperature control system is filled with the refrigerant, read the pressure gauge on the filling device at the very first, the rotate the scale sleeve, and the quantitative liquid line corresponding to the pressure gauge is found on the sleeve, and the initial level of the liquid surface of the refrigerant in the glass tube is recorded. Then open the three-way valve, the refrigerant enters the refrigeration system through the hose, and the liquid level of the refrigerant in the glass tube begins to decrease. When the required amount of filling is achieved, close the discharge chamber and the three links on the charging device and the charging operation end.
The temperature control system is used in many fields. Plastic, electronic. Electroplate。 Laser, food, textile, chemical industry. Packing。 Medical care。 Even in industries such as test and even beverage, the industrial refrigeration equipment and temperature control system group play a very important role in beer production line.