Chiller Refrigeration System SUNDI-320/420W/430W

 Technical Parameters of Dynamic Temp. Control System

Change the control settings of the method, the response as soon as possible in the process of the system lags behind, be the smallest system overshoot. Controlled by two PID (PID is a variable in each group) control loop structure, known as the two sets of control loops: the main circuit and from the circuit, the main control loop from the loop output as the settings.

Type
Temp range℃
Heating KW
Cooling capacity  KW  AT  ℃
Flow/pressure
L/min bar
Outside size
Power
180
50
0
-5
-20
-35
SUNDI-320
-30+180
2
1.5
1.5
1.5
0.9
0.6

10
0.8
400*600*800
2.9kw
SUNDI-420W
-40+180
2
1.8
1.8
1.8
1.2
1
0.3
10
0.8
400*600*800
3.3kw

Type
SUNDI/UST series
Control Mode
Feedback PID + Our special dynamic control calculation, Lneya PLC controller
Temp.control
Material reaction temp.control mode and jacket temp.control mode
Program Editor
10 programs, each program can edit 45 steps.
Communication Portocol
MODBUS RTU Protocol,RS485 interface
Optional  Ethernet interface/R232 interface
Temp.feedback
The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Material temp. feedback
Material temp. feedbackPT100 or 420mA or communication given
Temp.feedbackPT100
Temp. difference
Set or control oil outlet temp and reactor material temp. difference
Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)
Material temp.accuracy
±1℃ sometimes ±0.5℃
Thermal medium temp. accuracy
±0.5℃
Closed circulation system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
heating
 Heating max output power
 The heater has triple protection and independent temperature limiter to ensure the safety of heating system.
The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.
Cooling capacity
The power of taking away the heat at different temperature
Circulation flow rate and pressure
  Lower than 75L/min, use Lneya Magnetic pump
Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.
  Pressure selection: 2bar 3bar 5bar 8barsmall power equipment can not customize
 The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.
compressor
Different type different brand compress
Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.
evaporator
KAORIPlate heat exchanger
Oil separator
Emerson/Lneya
Drying filter
danfoss/Emerson
Shock tube
CASTEL/packless
voltage-controlled
danfoss/Emerson/fengsheng
Expansion valve
Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Select different expansion valves with different temperature and cooling capacity.

Operation panel
Lneya 7-inch touch screenshow temp curve\EXCEL data output
1Optional Siemens explosion - proof touch screen.Place the operation panel outside the site area.
2optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)
Safety protection
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
refrigerant
R-404A / R404A R23 mixture/ R404A R23 R14 mixture
interface size
G1/2G3/4G1DN25 DN32 DN40 DN50 DN65 DN80 DN100PN10 RF
Water-cooling W
 With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water
Water cooled condenser.
Tube heat exchanger, plate heat exchanger, tube condenser.
packlessshengKAORIJINDIANXIAOLING etc
power
AC 380V 50HZThree-phase five-wire system.  Small power 220V 50HZ single phase
Optional 460V 60HZ220V 60HZ three-phase  
Shell material
Standard shellSUS 304optional spraying plastics color 7035
Isolation of explosion-proof
optioanlEXdIIBT4)   
Lneya explosion-proof product installation license number.PCEC-2017-B025
Positive pressure explosion-proof
optioanl(EXPXdmbIICT4)The positive pressure system must be water-cooled type
Lneya explosion-proof product installation license numberPCEC-2017-B025
Self pressurizing system
Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.
KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).
KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).
KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)
Flow/pressure
Optional flow/pressure sensor, display flow and pressure on the touch screen.
Optional control flow/pressure.

One for two system
Optional one for two systems: the costis lower than one to one system.
One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.
High exothermic control
Customizable high heat control system algorithm and components.
flow reactor temperature control module.
It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units

Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today we will recommend a few solutions for you:

Increase cooling water flow and heat ventilation of water tank and water tower.
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.

Reduce the exhaust temperature of the refrigeration compressor directly.
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of compressor.

Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units

Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today we will recommend a few solutions for you:

Increase cooling water flow and heat ventilation of water tank and water tower.
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.

Reduce the exhaust temperature of the refrigeration compressor directly.
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of compressor.