Thursday, July 19, 2018

Introduction To The Preparation Of Low Temperature Chiller' Operation



Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.

Before running the low temperature chiller, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.

Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.

Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%--100%, then 100%--0%, then manually stop the oil pump.

Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 --55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.

With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.

Contact LNEYA for more dynamic temperature control equipments.

Monday, July 16, 2018

Refrigeration Principle Of Low Temperature Chiller



The refrigeration principle of the so-called low temperature chiller is to use the artificial method, compressor refrigeration, through energy consumption, in a cycle process, in the process that cooling materials take away the heat. Generally speaking, the compressor is use to refrigerate. With the refrigerant, the low boiling point material is used as the medium. The refrigerant is compressed in the compressor, the saturation temperature is higher than the ambient temperature, then it passed through the condenser and is condensed into liquid, liquefied through the throttle valve, and then the heat is absorbed by the cold medium to become the low pressure steam, finally it returns to the compressor cycle.

In addition to compressor refrigeration, there is ammonia refrigeration. However, the overall cost of compressor refrigeration is lower than that of ammonia refrigeration. So now, we tend to choose compressor refrigeration.

After understanding the principle of refrigeration, the selection of a series of equipment parameters such as water flow, outlet temperature and cooling capacity of low temperature chiller should be fully understood in order to make a better selection.

Of course, the refrigerants of low temperature chillers can be environmental refrigerants as far as possible, for the sake of more energy saving and environmental protection and in line with the demand of the public.

Contact LNEYA for more dynamic temperature control equipments.

Friday, June 8, 2018

Low Temperature Chiller LN -60℃~-10℃



    Low Temperature Chiller LN -60℃~-10℃




    -60℃~-10℃

     Technical Parameters:

    Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.
    ModelLN-6WLN-10WLN-15WLN-20WLN-30WLN-40WLN-60WLN-90WLN-120WLN-180W
    Temp. range-60°C~ -10°C
    Cooling capacity12kw20kw30kw40kw60kw80kw120kw180kw240kw360kw
    At -40°C Kcal/h103201720025800344005160068800103200154800206400309600
    Cooling capacity6kw10kw15kw20kw30kw40kw60kw90kw120kw180kw
    At -55°C Kcal/h516086001290017200258003440005160077400103200154800
    Circulation pump6.6m³/h9m³/h15m³/h15m³/h25m³/h25m³/h25m³/h35m³/h35m³/h50m³/h
    2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar2.5bar
    Connection sizeDN-25
    PN-10
    DN-25
    PN-10
    DN-32
    PN-10
    DN-32
    PN-10
    DN-40
    PN-10
    DN-40
    PN-10
    DN-40
    PN-10
    DN-50
    PN-10
    DN-50
    PN-10
    DN-65
    PN-10
    Cooling water  30 DEG10m³/h14m³/h20m³/h25m³/h30m³/h35m³/h50m³/h70m³/h90m³/h120m³/h
    Cool storage tank (optional)200L350L500L750L1000L1200L1500L2200L3000L4000L
    Expansion tank (optional)100L175L250L350L500L600L750L1000L1350L1800L
    CompressorStandard: Dorin semi-closed compressorStandard: Hanbell screw compressor
    Optional: Bitzer screw compressor
    Operation panel7 inch color touch screen display input, temperature curve record.
    Control systemStandard: single chip microcomputer controller, position setting to open refrigeration 
    and close refrigeration temperature difference.
    Optional: Siemens S7 series PLC and module.
    Circulation systemThe whole system is fully closed system. The heat conduction medium does not absorb 
    the water in the air and will be replenished automatically at low temperature. The system
    will not increase the pressure due to the high temperature in the operation.
    Circulation pumpWuxi guanya tube type centrifugal pump.
    EvaporatorStandard: Brazing plate heat exchanger.
    Optional: stainless steel tube heat exchanger.
    CondenserShell and tube type water cooled condenser.
    Intermediate heat exchangerPlate heat exchanger.
    Drying filterEmerson
    Dry filter elementEmerson
    Expansion valveEmerson
    Refrigeration solenoid valveEmerson
    Oil separatorEmerson
    Pressure protectorEmerson
    Reservoir
    Sight glassesStandard: Sanhua  Optional: Danfoss
    Refrigeration ball valveStandard: Sanhua  Optional: Danfoss
    ElectricitySchneider electric contact, schneider intermediate relay.
    RefrigerantR404A
    SecondaryrefrigerantNon-corrosive liquid, ethanol aqueous solution, thermal conductivity oil, etc.
    Security and protectionHigh pressure protection, water break protection, current protection, leakage protection,
    continuous and broken phase protection, high temperature protection, sensor fault alarm,
    low level alarm and other multiple security protection.
    Level indicatorGlass level indication.
    Piping materialSUS304
    Expansion tank volumeSUS304
    Shell materialChannel steel + square pipe + cold rolled steel
    Dimension cm180*120
    *175
    205*145
    *175
    205*145
    *175
    205*145
    *175
    235*145
    *175
    235*145
    *175
    350*150
    *205
    350*150
    *205
    400*180
    *205
    450*200
    *2050
    Power supply max380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    380V
    50HZ
    14kw18kw26kw35kw52kw69kw104kw152kw200kw300kw
    NoiseWithin 75dbWithin 80dbWithin 90db
    Weight850kg1000kg1200kg1450kg2000kg2400kg3000kg3600kg4200kg5600kg

    We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly reduce the service life of the them. Here, we will talk about major attention matters when enterprises use low temperature chillers!

    1. Refrigerant leakage

    Refrigerant leakage will not only affect the refrigeration efficiency of low temperature chillers, but also affect the health of people in and out of the engine room, so the issue of refrigerant leakage must be noted.

    2. Pay attention to the load of the low temperature chillers

    The large load of low temperature chillers, or overload phenomenon which is more than the rated load, will bring about serious problems including refrigeration efficiency decline, bigger noise,  bigger vibration amplitude, excessive consumption of resources, decline in service life and so on which need to pay attention to!

    3. Temperature and pressure

    It can be said that the parameters related to temperature and pressure are the most important parameters of low temperature chillers. Enterprises should pay attention to the parameters related to the temperature and pressure of the low temperature chillers, and solve them in time, so as to avoid affecting the normal operation of the low temperature chillers.

    Paying attention to the points mentioned above has extraordinary importance for extending the service life of low temperature chillers ,and improving the refrigeration efficiency and the use safety of low temperature chillers.



    Contact Lneya for more.