You Know What Technical Problems You Need to Know before You Buy A Low Temperature Chamber

Because the principle and structure of each low temperature chamber are very complex, but do you know what technical matters you need to know before buying its equipment? Next, I want to share with you several technical issues before purchasing the equipment. 

Question 1: Is the temperature change rate of temperature impact test the faster the better? 
Explanation: Is the temperature change rate faster and better in the temperature impact test? Does the temperature change rate have any effect on the test results? What kind of temperature change rate is the good impact temperature change rate?


Question 2: What should I do to shorten the test time? 
Explanation: When I do high temperature and humidity test or impact test, is there any way to shorten my test time so that the test results are the same? 

Question 3: How to distinguish the temperature shock and temperature cycle of low temperature chamber? 
Explanation: Where is the difference between temperature shock and temperature cycle, or are they all the same, just called differently? 

Question 4: Should the impact temperature be OVER or below the set value? 
Explanation: In the process of impact, should the impact temperature be higher or lower than the set value? 

Question 5: Question in the experiment: Points for holding the sample to be tested? 
Explanation: To put the test in the test furnace, how to get it right? 

Question 6: Does the low temperature chamber first flush high temperature or low temperature? 
Explanation: In the temperature impact test, how to decide if the specification does not require high temperature or low temperature first?

Thursday, July 18, 2019

Comparison of Three Test Methods for Low Temperature Chamber

1. Existence and absence of forced air test for heat dissipation test samples The method of guaranteeing the fluctuation of uniformity in high and low temperature test box is to adopt the wind circulation mode, in which the motor drives the fan to produce the wind circulation, thus forming the direction of wind speed. Non-forced air circulation test is a kind of test to simulate the influence of free air conditions, which is more suitable for the test of heat dissipation test samples. When forced air circulation is not used or test conditions are not guaranteed, forced air circulation can be used. One of the methods used in the test chamber is large enough to meet the test requirements without forced air circulation, but the required low temperature can not be maintained without forced air circulation in the chamber. Forced air circulation is required for refrigeration or heating of low temperature chamber

2. Non-heat dissipation test samples and heat dissipation test samples  When the temperature of the test sample is stable during the conditional test period, the hottest spot temperature on the surface of the test sample is higher than the ambient atmospheric temperature by 5 degrees under the condition of free air, which is considered to be heat dissipation, whereas the non-heat dissipation test sample is considered to be heat dissipation. All the storage test and the test period without power or load, the test samples are non-heat dissipation test samples, the test using low temperature test method. 

3. Non-heat dissipation test samples Temperature gradient test of low temperature chamber(the former is a rapid temperature change test box and the latter is a cryogenic tester). (1) Temperature gradient test: first, test samples with room temperature are put into the same room temperature test box. Then turn on the cold source to gradually cool the temperature in the box to the specified test temperature. If the test sample is too large or too heavy, or because of the complex functional test wiring, it can not be put into the cryogenic chamber without frosting in the catastrophe test, the test should also be used. (2) Temperature catastrophe test: first adjust the temperature of the test chamber to the specified test temperature, and then put the test sample with room temperature. This test method is applicable when the known temperature abrupt change does not produce operation on the test sample.