LNEYA Explosion Proof Refrigerator is a kind of special refrigerator mainly used for the special industrial environment to keep dangerous goods which are difficult to preserve, volatile and inflammable and explosive. With the development of petroleum, chemical industry, medicine, aerospace, military and other fields, the use of explosion-proof refrigerators is more and more frequent. However, in terms of technology, performance, technology, design and so on, few can meet the national standard.
As to the use of the refrigerator for the first time, you must follow the instructions, otherwise, improper operation may cause some unnecessary accidents. So you should carry out in accordance with the corresponding instructions to the operation and avoid freely use the machine with high precision, in order to avoid the loss of function of the equipment, which will cause more dangerous results.
Also, it should be noted that you can run it for one to six hours with an empty container when electrifying for the first time, so as to make sure the equipment is at a normal state, after which you can put the objects in it. Meanwhile, If the machine stops when running, you should wait at least five more minutes before it can be turned on again, so as not to damage the compressor in a short time. These small details noticed the use of such high-precision instruments will be easier.
Microcomputer control, cascade temperature controller, digital temperature display, the regulation of unit 0.1℃, inside the temperature range -20 ℃ ~ -125 ℃ adjustable.France TECUMSEH compressor, Germany DANFOSS compressor, EMERSON compressor, automatic cascade refrigeration technology.
With self-diagnosis function, freezer overload protection, high-pressure switches, overload relays, thermal protection device and other security functions, and fully guarantee the use of safety.Three sealed mold layer of insulation, Extra-thick high-density polyurethane foam insulation layer, the effect of good insulation; Inline vacuum insulation panels.
Human design, more convenient and flexible.
Cooling and heating program controlled, meet cold treatment process requirements(can set 5 programs,
each program can edit 45 steps.)Low temperature automatic defrost (can be once per hour or use manual button to defrost), ensure it can work at low temperature for long time even the door is open and close frequently).
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Wednesday, December 26, 2018
How to clean air control system?
In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the product, it is still necessary to have some knowledge of maintenance, and the most important thing to maintain is to say clean. Here, Guanya Refrigeration introduces some small methods for cleaning the air cooling system:
More traditional methods are scraping and brushing. Sweep the place where you need to clean and the brush. The dirt that cannot be easily wiped off can be scraped with a sword. The second step is to use high-pressure water or chemical cleaning (mainly pickling), only to get high-pressure water or chemical water in the place where there is dirt to carry out chemical reactions, so that the dirt can be off.
However, this more traditional method does not generally clean thoroughly, and cleaning with chemical water may also cause corrosion to the equipment and damage the machine. After the chemical waste has been washed away, it will take a lot of money to process it. Therefore, cleaning agents can be used. This is also relatively environmentally friendly, safe, and thorough in cleaning. Generally, oxidation does not occur, which is beneficial to the service life of the air cooling system.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
More traditional methods are scraping and brushing. Sweep the place where you need to clean and the brush. The dirt that cannot be easily wiped off can be scraped with a sword. The second step is to use high-pressure water or chemical cleaning (mainly pickling), only to get high-pressure water or chemical water in the place where there is dirt to carry out chemical reactions, so that the dirt can be off.
However, this more traditional method does not generally clean thoroughly, and cleaning with chemical water may also cause corrosion to the equipment and damage the machine. After the chemical waste has been washed away, it will take a lot of money to process it. Therefore, cleaning agents can be used. This is also relatively environmentally friendly, safe, and thorough in cleaning. Generally, oxidation does not occur, which is beneficial to the service life of the air cooling system.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Sunday, December 23, 2018
VOCS condensation price and maintenance instructions
The performance of VOCS condensing equipment is closely related to the VOCS condensing price. The proper VOCS condensing equipment is definitely superior in performance. What should be paid attention to in the maintenance of VOCS condensing equipment?LNEYA VOCS condensing equipment is used in various industries. LNEYA's VOCS condensing equipment is famous for its superior quality, affordable price and perfect after-sales. However, if VOCS condensing equipment is used properly, proper maintenance is required. VOCS condensing equipment operates more efficiently. When using VOCS condensing equipment, it is necessary to pay attention to carefully check the circuit system of VOCS condensing equipment, whether the test voltage is normal, lack of phase, whether the running current is stable, and whether the interlocking control circuit is loose or aging.
Shell-and-tube condensers and finned condensers are attached to the condenser due to the impurities in the water. If the time is too long, the heat dissipation effect will be affected. After the maintenance of the machine, the test machine will run and the total calibration will be performed to test whether the superheat is normal. Whether there is abnormal sound in each part.
Check whether the VOCS condensing equipment drying filter and expansion valve are normal, whether there is any blockage. If necessary, replace it. If it is cleaned regularly, install a filter at the water source to prevent trees and debris from entering the pipeline. Check the refrigeration compressor of the VOCS condensing unit and insulate the compressor motor coil. Check the refrigeration oil and lubricating oil system of the VOCS condensing equipment. If there is any shortage or mess, it should be replenished or replaced.
The maintenance of VOCS condensation price is more important. LNEYA recommends that users do maintenance work in a timely and effective manner, and strive to achieve VOCS condensation to achieve efficient operation.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Vocs condensation adsorption technology energy control instructions
The vocs condensation adsorption technology has been developed under the current trend of environmental protection. The LNEYA vocs condensation adsorption technology uses condensation adsorption technology. In order to save operating costs, it is recommended to do energy control.
In order to save the cost of using vocs condensation adsorption technology, users need to learn to control its energy consumption when using vocs condensation adsorption technology. To reduce the energy consumption of vocs condensation adsorption technology, we first need to provide good vocs condensation adsorption technology. Electricity environment. For example, the voltage of the electricity environment is relatively low, and the vocs condensation adsorption technology equipment must maintain the stable operation efficiency, which inevitably increases the consumption of electric energy, and the excessive voltage will inevitably lead to the operation failure of the vocs condensation adsorption technology.
It can provide safe voltage use conditions for vocs condensation adsorption technology, which is the basic condition for reducing the energy consumption of vocs condensation adsorption technology. It is suitable for voltage environment and effectively reduces the energy consumption of vocs condensation adsorption technology. If you want to control the performance of vocs condensing adsorption technology and maintain the safety and stability of the system, you need to develop a specific use plan, regardless of any equipment without a specific plan, will put the system in an overload state, which will seriously affect vocs condensation The quality of the adsorption technology.
Regular maintenance and repair of vocs condensation adsorption technology can maintain the stability of vocs condensation adsorption technology, no matter the lack of maintenance and repair of any equipment, will reduce the effectiveness. Of course, this maintenance is purposeful maintenance, for example, it can start from the system. As long as the maintenance work is done, the equipment can be used better and the efficiency will be greatly improved.
Since the environment has a great influence on the vocs condensation adsorption technology, while ensuring the quality, we must also pay attention to the environmental impact of the vocs condensation adsorption technology, and must not affect the environment when used.
The operating consumption and power of vocs condensing adsorption technology affect the operating cost of vocs condensing adsorption equipment. Therefore, enterprise vocs condensation adsorption technology must do a good job of reducing energy costs.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
In order to save the cost of using vocs condensation adsorption technology, users need to learn to control its energy consumption when using vocs condensation adsorption technology. To reduce the energy consumption of vocs condensation adsorption technology, we first need to provide good vocs condensation adsorption technology. Electricity environment. For example, the voltage of the electricity environment is relatively low, and the vocs condensation adsorption technology equipment must maintain the stable operation efficiency, which inevitably increases the consumption of electric energy, and the excessive voltage will inevitably lead to the operation failure of the vocs condensation adsorption technology.
It can provide safe voltage use conditions for vocs condensation adsorption technology, which is the basic condition for reducing the energy consumption of vocs condensation adsorption technology. It is suitable for voltage environment and effectively reduces the energy consumption of vocs condensation adsorption technology. If you want to control the performance of vocs condensing adsorption technology and maintain the safety and stability of the system, you need to develop a specific use plan, regardless of any equipment without a specific plan, will put the system in an overload state, which will seriously affect vocs condensation The quality of the adsorption technology.
Regular maintenance and repair of vocs condensation adsorption technology can maintain the stability of vocs condensation adsorption technology, no matter the lack of maintenance and repair of any equipment, will reduce the effectiveness. Of course, this maintenance is purposeful maintenance, for example, it can start from the system. As long as the maintenance work is done, the equipment can be used better and the efficiency will be greatly improved.
Since the environment has a great influence on the vocs condensation adsorption technology, while ensuring the quality, we must also pay attention to the environmental impact of the vocs condensation adsorption technology, and must not affect the environment when used.
The operating consumption and power of vocs condensing adsorption technology affect the operating cost of vocs condensing adsorption equipment. Therefore, enterprise vocs condensation adsorption technology must do a good job of reducing energy costs.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Description of operation characteristics of fully enclosed refrigeration and heating machine
In the petroleum, chemical, and pharmaceutical industries, fully enclosed refrigeration and heating integrated machines are needed by many enterprises. However, when users choose to make choices, they must understand their operating characteristics. LNEYA's refrigeration and heating integrated machine has been in the industry. The advanced position and operational advantages are also very obvious.
Typical application of a fully enclosed refrigeration and heating machine:
Fully enclosed refrigeration and heating machine for dynamic constant temperature control of high pressure reactor cold and heat source, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, constant temperature control of microchannel reactor cold and heat source , small thermostat control system, steaming system temperature control, material low temperature and high temperature aging test, combined chemical cold source heat source constant temperature control, semiconductor equipment cooling heating, vacuum chamber cooling heating constant temperature control.
Advantages and functions of a fully enclosed refrigeration and heating machine:
The fully enclosed refrigeration and heating unit has a temperature range from 120 ° C to 350 ° C. It has excellent performance, high precision and intelligent temperature control.
Fully enclosed refrigeration and heating integrated machine with high cooling power from 0.5 to 1200 kW, high production stability and repeatability results, as well as multi-function alarm system and safety functions, using plate heat exchangers, ducted heaters to improve heating and Cooling rate.
Fully enclosed refrigeration and heating machine is equipped with 7-inch, 10-inch color TFT touch screen graphic display, magnetic drive pump, no shaft seal leakage problem, fully enclosed system, extended thermal fluid life, very wide temperature range, no need to replace liquid medium.
The fully enclosed refrigeration and heating machine has a high temperature cooling technology, which can directly cool down from a high temperature of 300 degrees.
The principle and function of a fully enclosed refrigeration and heating machine has many advantages for the user: because only the heat transfer medium in the expansion chamber is in contact with the oxygen in the air (and the temperature of the expansion tank is between room temperature and 60 degrees). It is possible to reduce the risk of the heat transfer medium being oxidized and absorbing moisture in the air. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
Different enterprise users have different temperature requirements for fully enclosed refrigeration and heating integrated machines. Specifically, they should be carefully selected according to their own working conditions. If you do not know how to choose, you can consult with professional manufacturers of refrigeration and heating machines.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Typical application of a fully enclosed refrigeration and heating machine:
Fully enclosed refrigeration and heating machine for dynamic constant temperature control of high pressure reactor cold and heat source, dynamic constant temperature control of double-layer glass reactor cold and heat source, dynamic constant temperature control of double-layer reactor cold and heat source, constant temperature control of microchannel reactor cold and heat source , small thermostat control system, steaming system temperature control, material low temperature and high temperature aging test, combined chemical cold source heat source constant temperature control, semiconductor equipment cooling heating, vacuum chamber cooling heating constant temperature control.
Advantages and functions of a fully enclosed refrigeration and heating machine:
The fully enclosed refrigeration and heating unit has a temperature range from 120 ° C to 350 ° C. It has excellent performance, high precision and intelligent temperature control.
Fully enclosed refrigeration and heating integrated machine with high cooling power from 0.5 to 1200 kW, high production stability and repeatability results, as well as multi-function alarm system and safety functions, using plate heat exchangers, ducted heaters to improve heating and Cooling rate.
Fully enclosed refrigeration and heating machine is equipped with 7-inch, 10-inch color TFT touch screen graphic display, magnetic drive pump, no shaft seal leakage problem, fully enclosed system, extended thermal fluid life, very wide temperature range, no need to replace liquid medium.
The fully enclosed refrigeration and heating machine has a high temperature cooling technology, which can directly cool down from a high temperature of 300 degrees.
The principle and function of a fully enclosed refrigeration and heating machine has many advantages for the user: because only the heat transfer medium in the expansion chamber is in contact with the oxygen in the air (and the temperature of the expansion tank is between room temperature and 60 degrees). It is possible to reduce the risk of the heat transfer medium being oxidized and absorbing moisture in the air. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
Different enterprise users have different temperature requirements for fully enclosed refrigeration and heating integrated machines. Specifically, they should be carefully selected according to their own working conditions. If you do not know how to choose, you can consult with professional manufacturers of refrigeration and heating machines.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
Thursday, December 20, 2018
Accessories and accessories for heating and cooling systems
The selection of heating and cooling system is quite important, not only price and temperature control, but also quality should be taken into consideration. Besides, you should also pay attention to the accessories of heating and cooling system.Filter:
The installation of the filter in the pipeline is necessary, for it can effectively prevent the pipeline blockage, the deterioration of heat conduction media and other problems. The negligence about it may cause property loss and safety accidents. What's more, the filter needs to be cleaned or replaced regularly.
Pressure gauge:
The pressure gauge is the key in the cooling and heating equipment. It closely records the pressure of the pipeline and discovers the pressure state of the pipeline in time. It can find the high and low pressure problems in the pipeline in real time and modify it.
Pipe bypass:
The outlet and inlet of heating and cooling system should be connected by three-way and manual valve, then make a proper diversion according to piping pressure.
Manual valve:
Put manual valves on the connection of heating and cooling system and both ends of the components installation, thus the heating and cooling system can be easily disassembled in maintenance, so that reducing the loss of heat conduction medium, and the related valves can be closed in time when in trouble.
The parts of the heating and cooling system are not fully included above. In order to ensure the stable operation of the equipment, we should take full consideration of the temperature range, the pressure range, the use of the environment and other specific knowledge of the components.
Web:https://www.lneya.com
Mail:sales@cnzlj.com
LNEYA Low temperature thermostatic bath instructions
Low temperature thermostat is widely used in petroleum, chemical industry, electronic instruments, physical, chemical and biological engineering, medicine and health, life sciences, food industry, physical testing and chemical analysis and research departments, universities, enterprises and production quality inspection departments, for the user to work to provide a heat source temperature field controlled, uniform and constant constant temperature test, or test on the test samples or products, but also can be used as direct heating or cooling and heating or cooling cooling or heating.Low temperature thermostatic bath is widely used to provide a user with a controlled and uniform temperature field source, a constant temperature test for a test sample or a produced product be used as a heat source or cold source for direct heating or cooling or auxiliary heating or cooling.
1. The liquid medium must be added first in the low temperature or constant temperature bath before using, otherwise, the heater will be damaged when the electricity is working. The liquid surface of the medium should be lower 30mm than the working plate.
2. The selection of liquid medium in low temperature and constant temperature bath should be in accordance with the following principles:
3. When the working temperature is at 5℃~85 ℃, choose water as the liquid medium.
4. When the working temperature is at 85℃~95 ℃, choose 15% glycerol solution as the liquid medium.
5. When the working temperature is below 5 centigrade, choose alcohol or frozen liquid as the liquid medium.
6. When the cryogenic thermostat switch is closed, the refrigeration switch should be opened for a 10~20 minutes interval (depending on the ambient temperature).
7. Low temperature constant temperature bath power: 220V50Hz, the power of the power supply should be greater than the total power of the instrument. The power supply must have a good "grounding" device.
8. The low temperature and constant temperature bath should be placed in the dry and ventilated place, and there are no obstacles in the 300mm around the instrument. When low temperature and constant temperature bath temperature is low, don't put hands into the slot, in order to prevent frost injury. After using, all switches should be closed and the cut the power off. Clean the Low Temperature Thermostat Bath frequently and keep the work table and the operation panel clean.
Web:https://www.lneya.com
Mail:sales@cnzlj.com